Rockwell-automation 1734-485ASC POINT I/O ASCII User Manual Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 1734-485ASC POINT I/O ASCII User Manual. Rockwell Automation 1734-485ASC POINT I/O ASCII User Manual User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 76
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
POINT I/O ASCII
Modules
1734-232ASC, 1734-485ASC
User Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 75 76

Podsumowanie treści

Strona 1 - POINT I/O ASCII

POINT I/O ASCII Modules1734-232ASC, 1734-485ASCUser Manual

Strona 2 - Important User Information

Publication 1734-UM009B-EN-P - July 2003Table of Contents iiTransmit Handshake vs. Transmit Immediate Mode. . . . 2-24Transmitting Serial Data

Strona 3 - Rockwell Automation

1 Publication 1734-UM009B-EN-P - July 2003Chapter 1Installing the ASCII ModuleGeneral Information on the ASCII ModulesThe ASCII modules provide a flex

Strona 4

Publication 1734-UM009B-EN-P - July 20031-2 Installing the ASCII Module1. Position the mounting base/wiring base assembly vertically above the

Strona 5 - This Manual

Publication 1734-UM009B-EN-P - July 2003Installing the ASCII Module 1-3Installing an I/O ModuleThe module can be installed before, or after bas

Strona 6 - Documentation

Publication 1734-UM009B-EN-P - July 20031-4 Installing the ASCII ModuleInstalling the Removable Terminal BlockA removable terminal block is sup

Strona 7

Publication 1734-UM009B-EN-P - July 2003Installing the ASCII Module 1-5Removing a Mounting BaseTo remove a mounting base, you must remove any

Strona 8 - Preface 4

Publication 1734-UM009B-EN-P - July 20031-6 Installing the ASCII ModuleWiring the 1734-232ASC ModuleWiring the 1734-485ASC ModuleModule StatusN

Strona 9 - Table of Contents

Publication 1734-UM009B-EN-P - July 2003Installing the ASCII Module 1-7Module TerminationsTerminal RS-232 RS-485 RS-4220Tx1S+1Tx+11Rx2NC Rx+12N

Strona 10 - Table of Contents ii

Publication 1734-UM009B-EN-P - July 20031-8 Installing the ASCII ModuleCable Pinouts for Standard DB ConnectorsHow to Install a Serial NetworkT

Strona 11 - Installing the ASCII Module

Publication 1734-UM009B-EN-P - July 2003Installing the ASCII Module 1-95. The ASCII module produces and consumes the number of ASCII characters

Strona 12

Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use

Strona 13 - Installing an I/O Module

Publication 1734-UM009B-EN-P - July 20031-10 Installing the ASCII ModuleHow to Write Serial Output Data to the ASCII Module1. Connect to the AS

Strona 14 - Terminal Block

Publication 1734-UM009B-EN-P - July 2003Installing the ASCII Module 1-11Setting Up DeviceNet CommunicationsThe ASCII module supports 4 modes of

Strona 15 - Removing a Mounting Base

Publication 1734-UM009B-EN-P - July 20031-12 Installing the ASCII ModuleCyclic and Change of State I/OThe Cyclic and Change of State (COS) conn

Strona 16 - 1734-232ASC Module

Publication 1734-UM009B-EN-P - July 2003Installing the ASCII Module 1-13The transmit and receive sizes of the I/O connection are automatically

Strona 17 - CG = Chassis Ground

Publication 1734-UM009B-EN-P - July 20031-14 Installing the ASCII ModuleOperating Mode SelectionsThe ASCII module has several different operati

Strona 18 - How to Install a Serial

Publication 1734-UM009B-EN-P - July 2003Installing the ASCII Module 1-15Produce Immediate vs. Master/Slave Handshake OptionThis option defines

Strona 19 - ASCII Module

Publication 1734-UM009B-EN-P - July 20031-16 Installing the ASCII ModuleNotes:

Strona 20 - Data to the ASCII Module

1 Publication 1734-UM009B-EN-P - July 2003Chapter 2Configuring Your ASCII ModuleAbout CommunicationsThe ASCII modules have DeviceNet-to-serial link co

Strona 21 - Communications

Publication 1734-UM009B-EN-P - July 20032-2 Configuring Your ASCII ModuleConfiguration OverviewYou must use the RSNetworx for DeviceNet softwar

Strona 22

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-3What Does Auto Start Mode Do?When using Auto Start Mode, the adapter:1

Strona 23

Rockwell Automation SupportBefore you contact Rockwell Automation for technical assistance, we suggest you please review the troubleshooting informati

Strona 24 - Operating Mode Selections

Publication 1734-UM009B-EN-P - July 20032-4 Configuring Your ASCII ModuleAdding the ASCII Modules to Your NetworkFollow these steps:1. Start th

Strona 25 - Pad vs. No Pad Option

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-5Adding I/O Modules to Your NetworkAfter you add the communication devi

Strona 26

Publication 1734-UM009B-EN-P - July 20032-6 Configuring Your ASCII ModuleSetting the ASCII Module’s ParametersAfter adding the module to the ne

Strona 27 - Configuring Your ASCII Module

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-7Refer to the screens below for an explanation of its features.The modu

Strona 28 - Configuration Overview

Publication 1734-UM009B-EN-P - July 20032-8 Configuring Your ASCII ModuleChecking I/O Status and Viewing the EDS FileYou can view the I/O data

Strona 29 - What Does Auto Start Mode Do?

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-9Configuration AssemblyThe ASCII modules support a configuration assemb

Strona 30

Publication 1734-UM009B-EN-P - July 20032-10 Configuring Your ASCII ModuleParameter ListUse this table for information on configuring your ASCI

Strona 31

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-11Send (Produce) on DeviceNet to MasterReceive String Data Type8 Get/Se

Strona 32 - Module’s Parameters

Publication 1734-UM009B-EN-P - July 20032-12 Configuring Your ASCII ModuleSerial Port Transmit to ASCII DeviceMax Number of Transmit Chars17 Ge

Strona 33

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-13Serial Port Transmit/Explicit Messages from Configuration ToolTransmi

Strona 35 - Configuration Assembly

Publication 1734-UM009B-EN-P - July 20032-14 Configuring Your ASCII ModuleSequential AutoAddress29 Get Sequential AutoAddress will reassign the

Strona 36 - Parameter List

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-15POINT I/O ParametersReceiving Serial Data from the ASCII DeviceThe AS

Strona 37

Publication 1734-UM009B-EN-P - July 20032-16 Configuring Your ASCII ModuleSetting Up and Using Pad ModePad Mode operation adds extra characters

Strona 38

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-17Setting Up and Using the Swap Bytes ModeThis option may be helpful if

Strona 39

Publication 1734-UM009B-EN-P - July 20032-18 Configuring Your ASCII ModuleSetting Up and Using Delimiter OperationWhen receiving data strings f

Strona 40

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-19Setting Up the Scanner I/O Receive SizeThe ASCII modules automaticall

Strona 41 - POINT I/O Parameters

Publication 1734-UM009B-EN-P - July 20032-20 Configuring Your ASCII ModuleExplicit Messages to Receive the Serial Data StringParameters 14, 15,

Strona 42 - Setting Up and Using Pad Mode

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-21RX Parity Error (Bit 2)This bit is set if a parity error is detected

Strona 43 - Receive Byte Swapping

Publication 1734-UM009B-EN-P - July 20032-22 Configuring Your ASCII ModuleSetting Up the Transmit Character Buffer LengthThe Transmit Character

Strona 44 - Receive String Data Type

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-23Transmit String Data AssembliesTransmit String Data Assemblies are th

Strona 45

1 Publication 1734-UM009B-EN-P - July 2003PrefacePurpose of This ManualThis manual describes how to install, configure, and troubleshoot your POINT I/

Strona 46 - Status Byte Description

Publication 1734-UM009B-EN-P - July 20032-24 Configuring Your ASCII ModuleTransmit Handshake vs. Transmit Immediate ModeThis option defines whe

Strona 47 - Transmitting Serial Data to

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-25A transmission of the serial data from the ASCII module to your ASCII

Strona 48

Publication 1734-UM009B-EN-P - July 20032-26 Configuring Your ASCII ModuleTransmitting Serial DataThe length of the string sent determines the

Strona 49

Publication 1734-UM009B-EN-P - July 2003Configuring Your ASCII Module 2-27Produce Immediate vs. Master/Slave Handshake ModeSelecting the mode o

Strona 50

Publication 1734-UM009B-EN-P - July 20032-28 Configuring Your ASCII ModuleThe master monitors the new data flag and when the master is ready to

Strona 51

1 Publication 1734-UM009B-EN-P - July 2003Chapter 3DiagnosticsUsing the Indicators for TroubleshootingUse these indicators to help you troubleshoot an

Strona 52 - Transmitting Serial Data

Publication 1734-UM009B-EN-P - July 20033-2 DiagnosticsTable 3.2 Network Status IndicatorsIndication Probable CauseNetwork StatusOff Device is

Strona 53

1 Publication 1734-UM009B-EN-P - July 2003Appendix ASpecificationsSpecifications for the ASCII ModulesSpecifications - 1734-232ASC, -485ASC ModulesNum

Strona 54

Publication 1734-UM009B-EN-P - July 2003A-2 SpecificationsSpecifications - 1734-232ASC, -485ASC Modules (Continued)Receive Transaction ID 0-255

Strona 55 - Diagnostics

Publication 1734-UM009B-EN-P - July 2003Specifications A-3Specifications - 1734-232ASC, -485ASC Modules (Continued)EFT/B Immunity IEC 61000-4-4

Strona 56 - 3-2 Diagnostics

Publication 1734-UM009B-EN-P - July 2003Preface 2Related Products and DocumentationThe following table lists related POINT I/O products and doc

Strona 57 - Specifications

Publication 1734-UM009B-EN-P - July 2003A-4 SpecificationsNotes:

Strona 58 - °C (-40

1 Publication 1734-UM009B-EN-P - July 2003Appendix BUsing the ASCII Modules with the ControlLogix System Application ExamplesAbout These ExamplesFor t

Strona 59 - °C or greater

Publication 1734-UM009B-EN-P - July 2003B-2 Using the ASCII Modules with the ControlLogix System Application ExamplesEDS ConfigurationYou can c

Strona 60 - A-4 Specifications

Publication 1734-UM009B-EN-P - July 2003Using the ASCII Modules with the ControlLogix System Application Examples B-3DeviceNet Data DetailsWith

Strona 61 - About These Examples

Publication 1734-UM009B-EN-P - July 2003B-4 Using the ASCII Modules with the ControlLogix System Application ExamplesReading Data from the ASCI

Strona 62 - EDS Configuration

Publication 1734-UM009B-EN-P - July 2003Using the ASCII Modules with the ControlLogix System Application Examples B-5The following ControlLogix

Strona 63 - DeviceNet Data Details

Publication 1734-UM009B-EN-P - July 2003B-6 Using the ASCII Modules with the ControlLogix System Application ExamplesTransmitting Data from Con

Strona 64

Publication 1734-UM009B-EN-P - July 2003Using the ASCII Modules with the ControlLogix System Application Examples B-7The ladder logic below inc

Strona 65

Publication 1734-UM009B-EN-P - July 2003B-8 Using the ASCII Modules with the ControlLogix System Application ExamplesNotes:

Strona 66

Publication 1734-UM009B-EN-P - July 2003 1AAddingASCII module to network 2-4I/O module to network 2-5ASCII moduleadding to network 2-4communica

Strona 67

Publication 1734-UM009B-EN-P - July 2003Preface 3Counter Modules 24V Encoder/Counter Module (Cat. No. 1734-IK) Installation InstructionsUser Ma

Strona 68

Publication 1734-UM009B-EN-P - July 20032 KKeyswitch position 1-3MModeauto start 2-2data only 2-24handshake 1-15, 2-27immediate 1-15, 2-27no pa

Strona 69 - 1

Publication 1734-UM009B-EN-P - July 2003 3SScanner I/O receive sizesetting up 2-19Scanner I/O transmit sizesetting up 2-26Selectingoperating mo

Strona 70 - 2

Publication 1734-UM009B-EN-P - July 20034

Strona 71 - 3

Publication ICCG-5.21- January 2001 PN 955107-82How Are We Doing?Your comments on our technical publications will help us serve you better in the fut

Strona 72 - 4

Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST

Strona 74 - BUSINESS REPLY MAIL

Publication 1734-UM009B-EN-P - July 2003 8 PN 957782-64Supersedes Publication 1734-UM009A-EN-P - June 2002 Copyright © 2003 Rockwell Automation, Inc.

Strona 75

Publication 1734-UM009B-EN-P - July 2003Preface 4Notes:

Strona 76

i Publication 1734-UM009B-EN-P - July 2003Table of ContentsChapter 1Installing the ASCII ModuleGeneral Information on the ASCII Modules . . . . . . .

Komentarze do niniejszej Instrukcji

Brak uwag