Rockwell-automation 1734-SSI POINT I/O Synchronous Serial Interface Ab Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 1734-SSI POINT I/O Synchronous Serial Interface Ab. Rockwell Automation 1734-SSI POINT I/O Synchronous Serial Interface Absolute Encoder Module User Manual User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 53
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
POINT I/O
Synchronous Serial
Interface Absolute
Encoder Module
1734-SSI
User Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 52 53

Podsumowanie treści

Strona 1 - Encoder Module

POINT I/O Synchronous Serial Interface Absolute Encoder Module1734-SSIUser Manual

Strona 2 - Important User Information

Publication 1734-UM007D-EN-P - December 20051-2 Install the ModuleInstall the Mounting BaseThe wiring base assembly (1734-TB or 1734-TBS) consi

Strona 3 - Summary of Changes

Publication 1734-UM007D-EN-P - December 2005Install the Module 1-33. Press firmly to seat the mounting base on the DIN rail, noting that the mo

Strona 4 - Summary of Changes 2

Publication 1734-UM007D-EN-P - December 20051-4 Install the Module1. Using a bladed screwdriver, rotate the keyswitch on the mounting base cloc

Strona 5 - Table of Contents

Publication 1734-UM007D-EN-P - December 2005Install the Module 1-5Install the Removable Terminal BlockA removable terminal block comes with you

Strona 6 - 5000 Software

Publication 1734-UM007D-EN-P - December 20051-6 Install the ModuleRemove a Mounting BaseTo remove a mounting base, you must remove any installe

Strona 7 - Who Should Use This

Publication 1734-UM007D-EN-P - December 2005Install the Module 1-7Wire the Module Read this section for information about wiring the module.

Strona 8 - Documentation

Publication 1734-UM007D-EN-P - December 20051-8 Install the ModuleModule Terminations0D+11D-12V+3V-4 Shield5I16C+17C-11 D and C are RS422-type

Strona 9 - Install the Module

1 Publication 1734-UM007D-EN-P - December 2005Chapter 2Configure the ModuleAbout This ChapterRead this chapter for information about how to use RSNetW

Strona 10 - Install the Mounting Base

Publication 1734-UM007D-EN-P - December 20052-2 Configure the ModuleAdd I/O Modules to Your NetworkAfter you add the communication device, you

Strona 11 - Install a Module

Publication 1734-UM007D-EN-P - December 2005Configure the Module 2-3Set the Encoder’s ParametersAfter adding the module to the network, you mus

Strona 12

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Strona 13 - Terminal Block

Publication 1734-UM007D-EN-P - December 20052-4 Configure the Module2. Refer to the dialogs for an explanation of features.The module’s name ap

Strona 14 - Remove a Mounting Base

Publication 1734-UM007D-EN-P - December 2005Configure the Module 2-5Check I/O Status and View the EDS FileYou can view the I/O defaults setup,

Strona 15 - Wire the Module

Publication 1734-UM007D-EN-P - December 20052-6 Configure the ModuleClick View File to view the actual EDS file.Click the EDS File tab to displ

Strona 16 - 1-8 Install the Module

1 Publication 1734-UM007D-EN-P - December 2005Chapter 3Communicate with Your ModuleAbout This ChapterRead this chapter for information about how the 1

Strona 17 - Configure the Module

Publication 1734-UM007D-EN-P - December 20053-2 Communicate with Your ModuleByte Bit DescriptionProduce 8 7 6 5 4 3210Status Byte 0C2ST C1ST C2

Strona 18 - Add I/O Modules to Your

Publication 1734-UM007D-EN-P - December 2005Communicate with Your Module 3-3Communicate Real-time InformationThe Synchronous Serial Interface A

Strona 19 - Parameters

Publication 1734-UM007D-EN-P - December 20053-4 Communicate with Your ModuleFirmware Version 4.001 and above #123 (0x7B) Set/Get Run 1Gray/Bina

Strona 20

Publication 1734-UM007D-EN-P - December 2005Communicate with Your Module 3-5The following table shows the Instance Services provided by the Par

Strona 21 - Check I/O Status and View

Publication 1734-UM007D-EN-P - December 20053-6 Communicate with Your ModuleGray to Binary Conversion No/Yes Convert data from Gray to binarySS

Strona 22

1 Publication 1734-UM007D-EN-P - December 2005Chapter 4Set and Operate Your ModuleAbout This ChapterRead this chapter for information about setup and

Strona 23 - Communicate with Your Module

1 Publication 1734-UM007D-EN-P - December 2005Summary of ChangesThis publication contains new and revised information not in the last release.New and

Strona 24

Publication 1734-UM007D-EN-P - December 20054-2 Set and Operate Your ModuleData Rate The data rate is the SSI sensor’s communication rate (bits

Strona 25 - Information

Publication 1734-UM007D-EN-P - December 2005Set and Operate Your Module 4-3Sensor Resolution The number of steps per revolution for a rotary se

Strona 26

Publication 1734-UM007D-EN-P - December 20054-4 Set and Operate Your ModuleOperation of the Data Latch and Comparator FeaturesRead this section

Strona 27 - Operating Modes

Publication 1734-UM007D-EN-P - December 2005Set and Operate Your Module 4-5Comparators 1 and 2You can store two separate four-byte values and b

Strona 28 - Default values are in bold

Publication 1734-UM007D-EN-P - December 20054-6 Set and Operate Your ModuleAutomatic ModeThe purpose of the Automatic mode is to provide a mean

Strona 29 - Set and Operate Your Module

Publication 1734-UM007D-EN-P - December 2005Set and Operate Your Module 4-7Major module faults are indicated by the presence of the CCF and CCE

Strona 30

Publication 1734-UM007D-EN-P - December 20054-8 Set and Operate Your ModuleAt point B of the CLK signal is the rising clock edge. The sensor be

Strona 31

1 Publication 1734-UM007D-EN-P - December 2005Chapter 5Diagnose ProblemsAbout This ChapterRead this chapter for information about how to troubleshoot

Strona 32 - Operation of the Data Latch

Publication 1734-UM007D-EN-P - December 20055-2 Diagnose ProblemsIndication Probable Cause Recommended ActionNetwork StatusOff Device is not on

Strona 33 - Comparators 1 and 2

1 Publication 1734-UM007D-EN-P - December 2005Appendix AConfigure Modules in RSLogix 5000 SoftwareAbout This AppendixRead this appendix for informatio

Strona 34 - Other Module Features

Publication 1734-UM007D-EN-P - December 2005Summary of Changes 2Notes:

Strona 35 - 24-bit SSI Sensor

Publication 1734-UM007D-EN-P - December 2005A-2 Configure Modules in RSLogix 5000 SoftwareWhen you change Connection and Data Format, note the

Strona 36

Publication 1734-UM007D-EN-P - December 2005Configure Modules in RSLogix 5000 Software A-3Work with the Feedback DialogFollow these procedures

Strona 37 - Diagnose Problems

Publication 1734-UM007D-EN-P - December 2005A-4 Configure Modules in RSLogix 5000 Software For more information on these parameters refer to t

Strona 38 - 5-2 Diagnose Problems

Publication 1734-UM007D-EN-P - December 2005Configure Modules in RSLogix 5000 Software A-53. From the Conversion dialog, complete one of these.

Strona 39 - Communication Formats

Publication 1734-UM007D-EN-P - December 2005A-6 Configure Modules in RSLogix 5000 SoftwareWork with the Input Registration DialogFollow these p

Strona 40 - Use the Help Button

Publication 1734-UM007D-EN-P - December 2005Configure Modules in RSLogix 5000 Software A-7Work with the Watch Position DialogFollow these proce

Strona 41 - Work with the Feedback

Publication 1734-UM007D-EN-P - December 2005A-8 Configure Modules in RSLogix 5000 Software2. From the Watch Position dialog, make entries for A

Strona 42 - Work with the Conversion

Publication 1734-UM007D-EN-P - December 2005IndexNumerics1734-SSI moduleabout 1-124-bit SSI sensor 4-7AadaptersControlNet 1-1DeviceNet 1-1Ethernet/IP

Strona 43

Publication 1734-UM007D-EN-P - December 20052 IndexSSI word filter control 4-2SSI Word Length 4-1trailing bits 4-2module installation 1-3monito

Strona 44 - Registration Dialog

Publication CIG-CO521C-EN-P- May 2003 PN957782-91How Are We Doing?Your comments on our technical publications will help us serve you better in the fu

Strona 45 - Position Dialog

1 Publication 1734-UM007D-EN-P - December 2005Table of ContentsPrefacePurpose of This Manual. . . . . . . . . . . . . . . . . . . . . . . Preface-1Who

Strona 46

Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST

Strona 49 - How Are We Doing?

Publication 1734-UM007D-EN-P - December 2005 5 PN 957988-74Supersedes Publication 1734-UM007C-EN-P - August 2005 Copyright © 2005 Rockwell Automation

Strona 50 - BUSINESS REPLY MAIL

Publication 1734-UM007D-EN-P - December 2005Table of Contents 2Appendix AConfigure Modules in RSLogix 5000 SoftwareAbout This Appendix . . . .

Strona 51

1 Publication 1734-UM007D-EN-P - December 2005PrefacePurpose of This ManualRead this manual for information about how to install, configure, and troub

Strona 52

Publication 1734-UM007D-EN-P - December 20052 Preface Related Products and DocumentationFor specification, safety approval, and other infor

Strona 53 - Rockwell Automation

1 Publication 1734-UM007D-EN-P - December 2005Chapter 1Install the ModuleAbout This ChapterRead this chapter to learn about how to install, wire, and

Komentarze do niniejszej Instrukcji

Brak uwag