Installation InstructionsControlNet Modular Repeater AdapterCatalog Number 1786-RPA/BAbout the Repeater Adapter ModuleThe 1786-RPA/B ControlNet repeat
10 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011If the repeater adapter module does not snap i
ControlNet Modular Repeater Adapter 11Rockwell Automation Publication 1786-IN013F-EN-P - April 20116. Attach the DIN rail locks to the left side o
12 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 20117. Repeat steps 1 through 6 for each of the tw
ControlNet Modular Repeater Adapter 13Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Wire the Repeater Adapter ModuleThis section de
14 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Tighten the screws to 0.6…0.8 N•m (5…7 in•lb).
ControlNet Modular Repeater Adapter 15Rockwell Automation Publication 1786-IN013F-EN-P - April 20115. Connect the repeater adapter module to the C
16 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Status IndicatorsThe status indicators on the
ControlNet Modular Repeater Adapter 17Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Table 1 -Power-up and Fault ConditionsIndicator
18 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Table 3 -Repeater Modules Status IndicatorIndi
ControlNet Modular Repeater Adapter 19Rockwell Automation Publication 1786-IN013F-EN-P - April 2011SpecificationsTechnical Specifications - 1786-R
2 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Important User InformationSolid-state equipment
20 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Environmental Specifications - 1786-RPA/BAttri
ControlNet Modular Repeater Adapter 21Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Radiated RF immunityIEC 61000-4-310V/m with 1 k
22 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011CE European Union 2004/108/EC EMC Directive, c
ControlNet Modular Repeater Adapter 23Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Additional ResourcesThese documents contain add
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Rockwell Automation SupportRockwel
ControlNet Modular Repeater Adapter 3Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Environment and EnclosureATTENTION: This equipme
4 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011North American Hazardous Location ApprovalThe f
ControlNet Modular Repeater Adapter 5Rockwell Automation Publication 1786-IN013F-EN-P - April 2011European Hazardous Location ApprovalEuropean Zon
6 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Prevent Electrostatic DischargeFeatures and Com
ControlNet Modular Repeater Adapter 7Rockwell Automation Publication 1786-IN013F-EN-P - April 2011The repeater adapter also provides the following
8 ControlNet Modular Repeater Adapter Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Mount the Repeater Adapter ModuleThis section e
ControlNet Modular Repeater Adapter 9Rockwell Automation Publication 1786-IN013F-EN-P - April 2011Do these steps to mount the 1786-RPA/B module.1.
Komentarze do niniejszej Instrukcji