130Rockwell Automation Publication 1756-UM010B-EN-P - December 2011
130 Software Configuration Tags
I.Status[0].FillState Decimal SINT Displays current state of module for channel 0. The
following states are possible:
0 = Filler not active
1 = Filler Enabled only, waiting for start
2 = Timed Trickle Flow complete, not filled
3 = Full Flow for Fill function
4 = Timed Trickle Flow for Fill function
5 = Engineering units for Full Flow
6 = Engineering units for Trickle Flow
7 = Fill complete
I.Status[0].ConsumerErrorCode Decimal INT See page 120
I.Status[0].TotalCounts Decimal DINT Displays actual pulses counted by the counter
connected to the channel 0
I.Status[0].FreqAverage Float REAL Displays frequency averaged over the Meter samples
on channel 0
I.Status[0].FreqPeriod Float REAL Displays frequency using sample time on channel 0
I.Status[0].Speed Float REAL Displays frequency using filter resolution on channel 0
I.Status[0].Acceleration Float REAL Displays acceleration on channel 0 as calculated by
using AccelCalculation samples
I.Status[0].FillTotal Float REAL Fill total in engineering units
I.Status[0].GrossVolume Float REAL Total Counts during each Sample/K-factor x Meter
Factor as occurs on channel 0
I.Status[0].NetVolume Float REAL Total Counts during each Sample/K-factor x
MeterFactor x CCF) as occurs on channel 0
I.Status[0].GrossRate Float REAL Total Counts in Meter Sample/ (K-factor x Sample
Interval) x Meter Factor as occurs on channel 0
I.Status[0].NetRate Float REAL Total Counts in Meter Sample/ (K-factor x Sample
Interval) x Meter Factor x CCF as occurs on channel 0
I.Status[0].ProverTotal Float REAL Displays total counts (in engineering units) received on
channel 0 in prover operation.
Total resets when the ProverEnable feature is enabled.
This value operates concurrently with NetVolume, and
must be saved if subtracted from the NetVolume for
single and multiple prover verifications.
I.Status[1].ProverState Decimal SINT Displays status of the prover operation on channel 1
0 = Prover Not Active
1 = Prover waiting for 1
st
start
2 = Prover waiting for 1
st
stop
3 = Prover waiting for 2
nd
start
4 = Prover waiting for 2
nd
stop
5 = Prover Complete
Table 14 - Configurable Flowmeter Module Input Tags
Name Style Data type Definition