Publication 17715.45 - July 1997
Analog Input Module
(Catalog Number 1771-IFE/C)
Use this document as a guide when installing the 1771-IFE/C analog
input module.
To See page
Prevent Electrostatic Discharge Below
Understand Compliance to European Union Directives 2
Understand Product Compatibility 2
Calculate Power Requirements 3
Determine Module Placement 3
Set the A/B Simulation Jumper 3
Set the Configuration Jumpers 4
Key the Backplane Connector 4
Install the Module and Field Wiring Arm 5
Connect Wiring to the Field Wiring Arm 6
Ground the Chassis and Module 9
Configure the Module 10
For this reference information See page
Status Indicators 12
Troubleshooting 13
Specifications 13
CSA Hazardous Approval 15
Differences Between Series A, B and C Modules 16
The analog input module is sensitive to electrostatic discharge.
!
ATTENTION: Electrostatic discharge can damage
integrated circuits or semiconductors if you touch
backplane connector pins. Follow these guidelines
when you handle the module:
Touch a grounded object to discharge static potential
Wear an approved wrist-strap grounding device
Do not touch the backplane connector or
connector pins
Do not touch circuit components inside the module
If available, use a static-safe work station
When not in use, keep the module in its
static-shield box
This
icon is used when
additional information
is available in the
Analog
Input Module User Manual
,
publication 17716.5.1
15.
If you need a copy of this
manual, fax the enclosed
User Manual Request Card
to 18005766340. If you
are outside the U.S., fax the
card to13307234036.
Installation Instructions
Contents
Prevent Electrostatic
Discharge
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Analog Input Module

Publication 17715.45 - July 1997Analog Input Module(Catalog Number 1771-IFE/C)Use this document as a guide when installing the 1771-IFE/C analoginput

Strona 2 - Compatibility

Analog Input Module10Publication 17715.45 - July 1997Because of the many analog devices available and the wide varietyof possible applications, you

Strona 3 - Application

Analog Input Module 11Publication 17715.45 - July 1997Use the following table to read data from your input module.Dec. Bits 15 14 13 12 11 10 09 08

Strona 4 - Backplane Connector

Analog Input Module12Publication 17715.45 - July 1997Default ConfigurationIf a write block of five words with all zeroes is sent to the module,defau

Strona 5 - Field Wiring Arm

Analog Input Module 13Publication 17715.45 - July 1997Possible module fault causes and corrective action is described in thefollowing table.Indicato

Strona 6 - Connect Wiring to the

Analog Input Module14Publication 17715.45 - July 1997ValueDescriptionThermal Dissipation 8.52 BTU/hr (maximum)Unscaled BCD and binary output toproce

Strona 7 - Analog Input Module 7

Analog Input Module 15Publication 17715.45 - July 1997CSA Hazardous Location Approval Approbation d'utilisation dans des emplacements dangereux

Strona 8

Analog Input Module16Publication 17715.45 - July 1997Feature Series A, and B Series CIndicator lights 1. At power-up, the green run indicatorcomes o

Strona 9 - Ground the Chassis and Module

Analog Input Module2Publication 17715.45 - July 1997If this product has the CE mark it is approved for installation withinthe European Union and EEA

Strona 10 - Configure the Module

Analog Input Module 3Publication 17715.45 - July 1997The module receives its power through the 1771 I/O power supplyand requires 500mA from the back

Strona 11 - underrange/overrange bits

Analog Input Module4Publication 17715.45 - July 1997The module has configuration jumpers for determining the input type(voltage or current) desired

Strona 12 - Interpret Status Indicators

Analog Input Module 5Publication 17715.45 - July 1997!ATTENTION: Remove power from the 1771 I/Ochassis backplane and field wiring arm beforeremovi

Strona 13 - Specifications

Analog Input Module6Publication 17715.45 - July 1997Connect your I/O devices to the cat. no. 1771-WG wiring armshipped with the module.!ATTENTION:

Strona 14 - 17715.45 - July 1997

Analog Input Module 7Publication 17715.45 - July 1997- Jumper all unused channels to modulecommon to reduce noise.Source GroundChannel 1Channel 2Cha

Strona 15

Analog Input Module8Publication 17715.45 - July 1997Source Ground- Unused channels must have their + and inputs jumpered together and tied tomodule

Strona 16 - Series A, B and C Modules

Analog Input Module 9Publication 17715.45 - July 1997Ground the Chassis and ModuleUse the following diagrams to ground yourI/O chassis and analog in