Motion System Application Guide Chapter 7
Use the Auto Control Display
The Auto Control display lets you start, stop, hold, and restart the motion system. The state
machine section provides the status of the current motion system phase state.
Press Auto on the Application Navigation Bar. The Auto Control display opens.
Start and Run State Actions
Follow these steps to start your motion system and proceed to Run state.
1. Press Release Manual Control to release manual control.
If System Status Then
The Release Manual Control button is flashing Manual control was not released. Go to step 1.
The (green) Stopped state moves to Resetting and
then to Idle
Your system is ready to start. Go to step 2.
ATTENTION
Pressing Start will cause the system to jog.
Do not press Start if motion will cause personal injury or damage to
equipment.
Start Button
Stop Button
Application
Navigation Bar