Rockwell-automation 5370-CMPK Color CVIM Module MATH-PAK Instrukcja Użytkownika Strona 58

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 89
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 57
Chapter 4
Defining Formulas
443
output line, and assign both the High and Low FAULT RANGE limits to
another Results output line.
Formulas prevent the use of associated gage and window outputs: Any
formula you select and enable will disable the use of results outputs from a
corresponding gage or window (as listed in Table 4.A, page 43).
Entering Range Limits for Formulas
After you determine the appropriate FAULT RANGE and/or WARNING
RANGE limit values for a formula, you can enter these values using the
range/output setup table.
Define and enable formula first: A formula must be both defined and
enabled before you can enter range limits.
To access the range/output setup table for a formula:
Pick Range/Outputs on the Config. Results menu to display the
range/output table (see Figure 4.22).
Figure 4.22 Assigning range limits
Calculator pad
Inspection
statistics
table
Range/output
table
If all range limits are currently set to zero as shown in Figure 4.22, enter the
appropriate High and Low FAULT RANGE and/or WARNING RANGE
limits in the following order:
1. Pick the High box under FAULT RANGE. When you do, the calculator
pad appears, as shown in Figure 4.22.
Przeglądanie stron 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 88 89

Komentarze do niniejszej Instrukcji

Brak uwag