Rockwell-automation 5370-CMPK Color CVIM Module MATH-PAK Instrukcja Użytkownika Strona 65

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 89
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 64
Chapter 5
Analysis Functions and Runtime Displays
52
With MATH-PAK installed, the Color CVIM module allows you to select
whether you will include or exclude data from failed tools when collecting
statistics (when running the Color CVIM in learn mode).
You determine whether data from failed tools is included in the statistics
through the use of the Range Fail box on the Runtime Init. menu (see
Figure 5.2):
Pick Exit Runtime Init. to access the Runtime Init. menu.
Pick the Range Fail: box to toggle the setting between No Stats and
Stats.
The effects of the Range Fail selection are as follows:
Stats: Statistics collected will include results from failed tools as well as
from tools which pass.
No Stats: Statistics collected will include results only from tools which
pass.
Figure 5.2 The Range Fail box
Range Fail box
Statistics (Learn Mode) for
Failed Tools
Przeglądanie stron 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 88 89

Komentarze do niniejszej Instrukcji

Brak uwag