Podsumowanie treści

Strona 1 - User Manual

Rockwell Automation ControlLogix AutoMax DCSNet and AutoMax Remote I/O Communication Interface Module (Cat. No. 56AMXN/B) User Manual

Strona 2 - Important User Information

Page 10 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Installation Prevent Electrostatic Discharge The module i

Strona 3

AutoMax DCSNet/RE RIO Module Page 11 Publication number 56AMXN-UM002A-EN-P November 2002 error message on the 4-character display but does not enter

Strona 4

Page 12 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Figure 2 Inserting the 56AMXN Cabling and Termination U

Strona 5

AutoMax DCSNet/RE RIO Module Page 13 Publication number 56AMXN-UM002A-EN-P November 2002 The network coaxial cable must be terminated with 75 ohm te

Strona 6 - Overview

Page 14 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Quick Start The following sections provide a brief summar

Strona 7

AutoMax DCSNet/RE RIO Module Page 15 Publication number 56AMXN-UM002A-EN-P November 2002 8. You can now write your ladder logic using the tags you

Strona 8

Page 16 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Connections and Tags Connections When you add a 56AMXN to

Strona 9 - Other Requirements

AutoMax DCSNet/RE RIO Module Page 17 Publication number 56AMXN-UM002A-EN-P November 2002 will see the same input data as the ControlLogix with the o

Strona 10 - Installation

Page 18 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Figure 3 Configuration Tag The Configuration tag consis

Strona 11

AutoMax DCSNet/RE RIO Module Page 19 Publication number 56AMXN-UM002A-EN-P November 2002 InputDropMap Value Description 1 to 55 Drop data from dro

Strona 12 - Cabling and Termination

Page 2 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Important User Information Solid state equipment has oper

Strona 13 - Software Installation

Page 20 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 For example, you can inhibit the connection, then remove

Strona 14 - Quick Start

AutoMax DCSNet/RE RIO Module Page 21 Publication number 56AMXN-UM002A-EN-P November 2002 Bits Description 0-6 Input mapped drop offline 8-14 Outp

Strona 15

Page 22 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Register 16 contains CRC errors. This counter increments

Strona 16 - Connections and Tags

AutoMax DCSNet/RE RIO Module Page 23 Publication number 56AMXN-UM002A-EN-P November 2002 Configuring the Module in RSLogix 5000 You configure the mo

Strona 17 - Configuration Tag

Page 24 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 4. Assign the module a Name and optionally a Descriptio

Strona 18

AutoMax DCSNet/RE RIO Module Page 25 Publication number 56AMXN-UM002A-EN-P November 2002 The network update time is approximately 3 ms per drop (see

Strona 19

Page 26 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Figure 6 Module Properties 1 7. Set the module RPI. Th

Strona 20 - I and O Tags

AutoMax DCSNet/RE RIO Module Page 27 Publication number 56AMXN-UM002A-EN-P November 2002 Figure 7 Module Properties Dialog 1 4. Assign the modul

Strona 21

Page 28 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Figure 8 Module Properties Dialog 2 Connection Parameter

Strona 22

AutoMax DCSNet/RE RIO Module Page 29 Publication number 56AMXN-UM002A-EN-P November 2002 until the connection is closed and reopened, for example, b

Strona 23 - DCS Master or Slave

56AMXN/B AUTOMAX DCSNET/RE RIO MODULE 6 Overview 6 Differences from the 56AMXN/A 7 Hardware Features 9 Other Requirements 9 INSTALLATION 10 Pre

Strona 24

Page 30 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Figure 9 Module Properties 1 3. Assign the module a Na

Strona 25

AutoMax DCSNet/RE RIO Module Page 31 Publication number 56AMXN-UM002A-EN-P November 2002 Figure 10 Module Properties 2 12. Set the module RPI. T

Strona 26 - Remote I/O Master

Page 32 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Using the DCS Configuration Program The DCS Configuration

Strona 27

AutoMax DCSNet/RE RIO Module Page 33 Publication number 56AMXN-UM002A-EN-P November 2002 updates the bridged drop. If the data was just about to be

Strona 28

Page 34 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Figure 14 Bridging 7. For the Type, select DCS_REG to o

Strona 29 - Importing Tags

AutoMax DCSNet/RE RIO Module Page 35 Publication number 56AMXN-UM002A-EN-P November 2002 Using the 56AMXN as a Remote I/O Master As a Remote I/O mas

Strona 30

Page 36 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 5. Run RSLogix 5000 and configure the module. 6. Import

Strona 31

AutoMax DCSNet/RE RIO Module Page 37 Publication number 56AMXN-UM002A-EN-P November 2002 Figure 15 56AmxnRioCfg The tree is divided into three mai

Strona 32 - DCS Bridging

Page 38 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Remote I/O Tags 56AmxnRioCfg creates a tag file that cons

Strona 33

AutoMax DCSNet/RE RIO Module Page 39 Publication number 56AMXN-UM002A-EN-P November 2002 Using the MSG Instruction to Access 56AMXN Data You can use

Strona 34

Page 4 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Remote I/O Master 26 Using the Configuration Signature 2

Strona 35 - Procedure

Page 40 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 of service, instance, and attribute makes it possible to

Strona 36 - The Network Tree

AutoMax DCSNet/RE RIO Module Page 41 Publication number 56AMXN-UM002A-EN-P November 2002 Service (hex) Name Function 04h Set Attribute List Set th

Strona 37

Page 42 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Length (bytes)Destination Enter the destination tag name

Strona 38 - The Configuration Signature

AutoMax DCSNet/RE RIO Module Page 43 Publication number 56AMXN-UM002A-EN-P November 2002 you would write to registers 0-31 as a DCS slave and to reg

Strona 39 - DCS Data Object

Page 44 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 In the source tag, the data consists of: # of attribute

Strona 40

AutoMax DCSNet/RE RIO Module Page 45 Publication number 56AMXN-UM002A-EN-P November 2002 Length (bytes)Destination Destination tag name Table 13 Ge

Strona 41 - Instance Level Services

Page 46 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Instance 1 for registers 0-31 2 for registers 32-63 Attr

Strona 42

AutoMax DCSNet/RE RIO Module Page 47 Publication number 56AMXN-UM002A-EN-P November 2002 For instance 2, the size must be 16 (8 words). The command

Strona 43

Page 48 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 DCS Raw Read, Service Code 33h The DCS raw read command

Strona 44

AutoMax DCSNet/RE RIO Module Page 49 Publication number 56AMXN-UM002A-EN-P November 2002 Message Type CIP generic Service Type Custom Service Code

Strona 45

LEDs 61 NET LED – DCS/RIO Network Status 61 CLX LED – ControlBus Status 61 OK LED – Module Health 62 All LEDs Red 62 4-Character Display 62 Usi

Strona 46

Page 50 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 4 128 5 160 6 192 7 224 If you create an array organized

Strona 47

AutoMax DCSNet/RE RIO Module Page 51 Publication number 56AMXN-UM002A-EN-P November 2002 … Data for the first drop in the list, 32 words # of drops

Strona 48

Page 52 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Create a MSG instruction using the service code, class, i

Strona 49

AutoMax DCSNet/RE RIO Module Page 53 Publication number 56AMXN-UM002A-EN-P November 2002 Using DDE/OPC to Access DCS Data on the Module You can use

Strona 50

Page 54 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Using the Monitor Program 56AmxnMon is a program that let

Strona 51

AutoMax DCSNet/RE RIO Module Page 55 Publication number 56AMXN-UM002A-EN-P November 2002 Monitoring DCS Registers Select Monitor/DcsRegs to monitor

Strona 52

Page 56 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 By default the register contents are shown in decimal. Un

Strona 53

AutoMax DCSNet/RE RIO Module Page 57 Publication number 56AMXN-UM002A-EN-P November 2002 By default the contents of the registers are shown in decim

Strona 54 - Using the Monitor Program

Page 58 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 • Msg Recv, counts packets successfully received by the

Strona 55 - Monitoring DCS Registers

AutoMax DCSNet/RE RIO Module Page 59 Publication number 56AMXN-UM002A-EN-P November 2002 Active Drop List The Active Drop List shows which DCS drop

Strona 56 - Monitoring CLX Registers

56AMXN/B AutoMax DCSNet/RE RIO Module Overview This document is a user guide for the 56AMXN/B module, which allows a Rockwell Automation ControlLogi

Strona 57 - Monitor Diagnostics

Page 60 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Fatal Errors Fatal errors occur when the firmware on the

Strona 58

AutoMax DCSNet/RE RIO Module Page 61 Publication number 56AMXN-UM002A-EN-P November 2002 Troubleshooting LEDs The 56AMXN module has three LEDs that

Strona 59 - The Copy Table

Page 62 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 OK LED – Module Health A bicolor OK LED indicates module

Strona 60 - Fatal Errors

AutoMax DCSNet/RE RIO Module Page 63 Publication number 56AMXN-UM002A-EN-P November 2002 Message Description Depth=xx the drop number and drop dept

Strona 61 - Troubleshooting

Page 64 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 You can use 56AmxnMon to display the active drop list and

Strona 62 - 4-Character Display

AutoMax DCSNet/RE RIO Module Page 65 Publication number 56AMXN-UM002A-EN-P November 2002 56AMXN refuses a connection from the processor, an error wi

Strona 63

Page 66 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 • Minor fault • Internal state • Configured • Owned •

Strona 64 - Connection Tab

AutoMax DCSNet/RE RIO Module Page 67 Publication number 56AMXN-UM002A-EN-P November 2002 Updating the Firmware The card supports firmware and FPGA u

Strona 65 - Module Info Tab

Page 68 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 DCS Network Update Time From the manual for the 57C404B (

Strona 66 - Backplane Tab

AutoMax DCSNet/RE RIO Module Page 69 Publication number 56AMXN-UM002A-EN-P November 2002 Specifications The 56AMXN/B is a standard ControlLogix modu

Strona 67 - Updating the Firmware

AutoMax DCSNet/RE RIO Module Page 7 Publication number 56AMXN-UM002A-EN-P November 2002 • Supports up to 248 words of scheduled output data and 250

Strona 68 - DCS Network Update Time

Page 70 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 Support Local Drive Solutions Contact Directory New En

Strona 70 - Support

www.rockwellautomation.com Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 532

Strona 71

Page 8 AutoMax DCSNet /RE RIO Module Publication number 56AMXN-UM002A-EN-P November 2002 In remote I/O operation, if the ControlLogix was in progr

Strona 72

AutoMax DCSNet/RE RIO Module Page 9 Publication number 56AMXN-UM002A-EN-P November 2002 Hardware Features The following diagram shows the features

Komentarze do niniejszej Instrukcji

Brak uwag