5–6 OCI Data Server CNC Commands
Publication 8520-6.6 - August 1999
TRANSFER_AMP_TO_PORTB (no argument)
Use this command to back up the current AMP configuration to a
device connected to the control’s port B
. This will back up
configuration currently in RAM. This may or may not be the same
configuration stored in the control’s backup memory.
For example:
[TRANSFER_AMP_TO_PORTB]
writes the AMP configuration to the device connected to the
control’s port B. This backup file is not in a man–readable format.
If you require a man–readable version of AMP refer to the ODS
document utility. Use the command TRANSFER_AMP_FROM_
PORTB to retrieve an AMP configuration from a peripheral device.
Important: This command does not apply to the 9/PC CNC.
TRANSFER_HOMECAL_TO_PORTA (no argument)
Use this command to send the current home calibration data to a
printer or other device connected to the control’s port A
. This will
print the home calibration data currently in RAM. This may or may
not be the same home calibration data stored in the control’s backup
memory.
For example:
[TRANSFER_HOMECAL_TO_PORTA]
prints the home calibration data to the device connected to the
control’s port A. You can only use this command to output home
calibration data to a printer.
Important: This command does not apply to the 9/PC CNC.