OCI CommandsB–6
Publication 8520-6.6. - August 1999
Inst
ID
P3 typeParameter 3P2 typeParameter 2P1 typeParameter 1Dual
Proc.
# ParamsOCI / 9/PCControl TypeCommand DescriptionItem (Name)
153 COPY_PART_PROGRAM_FOR_EDIT Copies part program to/from OCI for editing All Controls Both No
132 COPY_MEM_TO_MEM Copies part program file memory to memory All Controls Both 3 No Source File Name STRING1 Dest File Name STRING1 Test(0)/Exec(1) DINT
133 COPY_MEM_TO_PORTA Copies part program file memory to port A All Controls OCI 3 No Source File Name STRING1 Copy to type enum DINT Test(0)/Exec(1) DINT
134 COPY_MEM_TO_PORTB Copies part program file memory to port B All Controls OCI 3 No Source File Name STRING1 Copy to type enum DINT Test(0)/Exec(1) DINT
135 COPY_PORTA_TO_MEM Copies part program file port A to memory All Controls OCI 3 No Dest File Name STRING1 Copy from type
enum
DINT Test(0)/Exec(1) DINT
136 COPY_PORTB_TO_MEM Copies part program file port B to memory All Controls OCI 3 No Dest File Name STRING1 Copy from type
enum
DINT Test(0)/Exec(1) DINT
3 DEACTIVATE_PART_PROGRAM Deactivates part program All Controls Both Yes
9 DELETE_PART_PROGRAM Deletes part program All Controls Both 1 No File Name STRING1
114 ENTER_PART_PROGRAM_
SEARCH_MODE
Enters part program search mode All Controls Both 1 Yes Search Type enum DINT
11 5 EXECUTE_PART_PROGRAM_SEARCH Executes part program search All Controls Both 1 Yes Search Method enum DINT
14 REFORMAT_MEMORY Reformats part program memory All Controls Both No
12 RENAME_PART_PROGRAM Renames part program All Controls Both 2 No File Name 1 STRING1 File Name 2 STRING1
6 SEQUENCE_STOP_PART_PROGRAM Sequence stop part program All Controls Both 1 Yes Stop Sequence No DINT
15 SET_DIRECTORY Sets directory All Controls Both 2 No Target Directory DINT enum Password STRING1
11 SET_PART_PROGRAM_COMMENT Sets comments for part program All Controls Both 2 No File Name STRING1 Comment String STRING1
13 SET_PART_PROGRAM_INPUT_DEVICE Inputs device All Controls Both 1 Yes Source of Part Prog
enum
DINT
11 6 SET_PART_PROGRAM_SEARCH_
PATTERN
Sets part program search pattern All Controls Both 1 Yes Search Pattern STRING1
10 VERIFY_PART_PROGRAM Verifies part program All Controls Both 3 No File Name 1 STRING1 File Name 2 STRING1 Source of Part Prog enum DINT
121 VERIFY_WITH_PORTA Verifies part program with port A All Controls OCI 2 Yes File Name STRING1 Test(0)/Exec(1) DINT
122 VERIFY_WITH_PORTB Verifies part program with port B All Controls OCI 2 Yes File Name STRING1 Test(0)/Exec(1) DINT
Part Program Execution
117 ENTER_MIDSTART_SEARCH_MODE Enters midstart search mode All Controls Both 1 Yes Midstart Type enum DINT
11 8 EXECUTE_MIDSTART_SEARCH Executes midstart search All Controls Both 1 Yes Midstart Search Mode
enum
DINT
11 9 SET_MIDSTART_SEARCH_PATTERN Sets midstart seach pattern All Controls Both 1 Yes Search Pattern STRING1
38 STOP_QUICK_CHECK Stops Quick Check All Controls Both Yes File Name STRING1
37 SYNTAX_QUICK_CHECK Quick Checks syntax All Controls Both Yes
Tool Management/Random Tool
26 ACTIVATE_RANDOM_TOOL Activates random tool "Lathe, Mill,
Dual"
Both 3 Yes Tool Number DINT Pockets Needed DINT Shaft Pocket DINT
25 BACKUP_RANDOM_TOOL Backup random tool data to part program "Lathe, Mill,
Dual"
Both 1 Yes File Name STRING1
24 BACKUP_TOOL_MANAGE Backup tool management data to part program "Lathe, Mill,
Dual"
Both 1 Yes File Name STRING1