7-- 12 Using ODS Communication Configuration
Publication 8520-- UM051A--EN--P -- October 2000
Offline DevelopmentManual (ODS) SoftwareUser Manual
Refer to Figure 7.10 to see t he menu flow used to configure RSLinx
for Ethernet.
Figure 7.10
Configuration Flow for Using RSLinx for Ethernet (CNCs o nly)
1.
2.
RSLinx for Ethernet
RSLinx StationAddress
of 9/Series
AB_ETH
DriverNumber
Select the appropriate driver number for your configuration
This number corresponds to theAB_ETH driver configured in
RSLinx for Ethernet communication. The driver range is 01 to
64 (decimal). The default value is 01.
Select the station address that was mapped to the 9/Series control’s
IP address during RSLinx configuration. The address range is 0 to
63 (decimal). The default value is 0.
After you edit and save your AMP file, download it to t he 9/PC so
that it is the currently active AMP file. You can use ODS to
download AMP files three ways:
from the local host PC i nto the 9/PC (refer t o page 5--3)
from a separate network--connected ODS workstation that is
running Windows NT t o t he host PC and into the 9/PC card
from an ODS workstation running Microsoft Windows NT and
Dial--up Networking, connected to the serial port of the host PC
running Microsoft’s’ Remote Access Services (RAS), and into the
9/PC card
In all cases, t he information you enter when creating the project is
used to direct the download to the correct 9/PC for this project. This
includes the host PC name and the topic name of the 9/PC card. This
project information can be changed at any time.
Configuring RSLinx for
Ethernet
Downloading AMP Files
for Use with the 9/PC