Minimum Speed Trimpot Range (% of rated voltage) 0to50%
Torque Trimpot Maximum Setting (% of maximum current) 200%
IR Drop Compensation (% of rated armature voltage) 0to15%
Acceleration Time Range 0.5 – 10 seconds
Deceleration Time Range 0.5 – 10 seconds
Analog Input Signal Range (S1 to S2) 0 – 10 VDC or 4 – 20 mADC
Input Impedance (S1 to S2) >100 KOHMS
Speed Regulation (% of base speed with 95% load change)
With Armature Feedback 1% or better
With Tachometer Feedback 0.1%
Speed Range 60:1
Tachometer Feedback Voltage Range
7 – 50 VDC per 1000 RPM
Maximum Current Load 150% for 1 minute
Safety Certification UL Listed Component
cUL Listed Component
CE Approved Component
Weight 2.1 lbs (953g)
Service Conditions
Maximum Allowable Elevation
3300 ft (1000 m) max without derating*
Vibration 0.5G max. (0–50 Hz); 0.1G max. (>50 Hz)
Ambient Temperature Range
Chassis Drives 10°C – 55°C
Enclosed Drives 10ºC – 45ºC
Non-condensing Relative Humidity 0% to 95%
* Derate the current by 1% for every 300 ft (90m) above 3300 ft., up to 10,000 ft.
(3000m)
2 Specifications