Rockwell-automation DC3E Non-Regenerative DC Drive User Guide 1/4 - 2 Instrukcja Użytkownika Strona 88

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 87
80 CE Compliance
If the end-user is using a CE-approved motor, the correct
filter from Table 5 is all that is necessary to meet the EMC
directives listed herein.
Armature Filters
If the end-user is not using a CE-approved motor, a
Reliance Electric CEXXMM filter must be deployed on the
output. XX is the rated current on the filter
The CE20MM is a Real-Pole Balanced-Pi 3-pole filter. If
the exact filter is not available, the specifications are as
follows:
L&L1=2*(0.8)milliHenries.
C&C1=2*(0.1) microFarads @ 400W VDC.
Rin = 0.1 ohm; Rout = 1.2 ohm.
Table 6. Armature Filters
Nameplate Current of
Motor Wired Reliance Electric© Filter
to the Drrive Part Number
0 to 4 amps CE04MM
4.1 to 13 amps CE20MM
250-0287-rev2.qxd 3/12/01 10:27 AM Page 80
Przeglądanie stron 87
1 2 ... 83 84 85 86 87 88 89 90 91 92

Komentarze do niniejszej Instrukcji

Brak uwag