Chapter 5 –Programming
5-7
Metering Group (cont.)
D
iv
m
]
Parameter # 70 Factory Default None
D
iv
m
]
Parameter Type Read Only Minimum 0
This parameter displays the drive internal temperature. Units 1_C Maximum Not Applicable
st F
u
t]
Parameter # 4 Factory Default None
st F
u
t]
Parameter Type Read Only Minimum 0
This parameter displays the fault code for the present drive
fault. If there is no active fault, the value will be zero.
Units Numeric Maximum Max. Fault Number
ut
ut
w
]
Parameter # 3 Factory Default None
ut
ut
w
]
Parameter Type Read Only Minimum 0 %
This parameter displays the percent of drive rated output
power.
Units 1 % Maximum 200% Drive Rated
Power
ut
ut Cu
]
Parameter # 2 Factory Default None
ut
ut Cu
]
Parameter Type Read Only Minimum 0 %
This parameter displays the percent of drive rated output
current.
Units 1 % Maximum 200% of Rated Drive
Output Current