7-24
Options
Figure 7.20 Typical Wiring Diagram for the Slow Speed with Braking Option
with a Bypass Contactor
Customer supplied.
Refer to the controller nameplate to verify the rating of the control power input voltage.
Note: Refer to Chapter 3 for typical power circuits.
Brake
Stop
BC
Control Power
Slow Speed
Start
11 12
13 14 15 16 17 18 19 20
21 22
23 24 25 26 27 28 29 30
Internal
Auxiliary
Contacts
To
Bulletin 825
Converter
Module
Auxiliary contacts set
for Up-to-speed
Fanning Strip
SMC Dialog Plus
Control Terminals