Rockwell-automation 1734-ADNX POINT I/O DeviceNet Adpater User Manual Instrukcja Użytkownika Strona 119

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 136
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 118
Publication 1734-UM002C-EN-P - July 2003
Default Data Maps D-5
Message size: 1 Byte
1734-OV2E Protected Sink Output Module
Message size: 1 Byte
Message size: 1 Byte
1734-OV4E Protected Sink Output Module
Message size: 1 Byte
Message size: 1 Byte
7 6 5 4 3 2 1 0
Consumes (scanner Tx) Not used Ch3 Ch2 Ch1 Ch0 Channel state
Where: 0 = Off 1 = On
7 6 5 4 3 2 1 0
Produces (scanner Rx) Not used Ch1 Ch0 Channel status
Where: 0 = no error 1 = error
7 6 5 4 3 2 1 0
Consumes (scanner Tx) Not used Ch1 Ch0 Channel state
Where: 0 = OFF 1 = ON
7 6 5 4 3 2 1 0
Produces (scanner Rx) Not used Ch3 Ch2 Ch1 Ch0 Channel status
Where: 0 = no error 1 = error
7 6 5 4 3 2 1 0
Consumes (scanner Tx) Not used
Ch3 Ch2
Ch1 Ch0 Channel state
Where: 0 = OFF 1 = ON