Rockwell Automation Publication 1788-UM059A-EN-P - August 2014 33
Chapter 4
USB Cable
Connect via USB to the
Linking Device
To use the USB port of the linking device, you must have RSLinx software,
version 2.56 or later, installed on your workstation. Use a USB cable to connect
your workstation to the USB port of the linking device.
With this connection, you can configure the linking device and the DeviceNet
network or upgrade the linking device’s firmware, directly from your workstation.
The USB port is on the front of the linking device.
ATTENTION: The USB port is intended only for temporary connections. The USB
cable is not to exceed 3.0 m (9.84 ft) and must not contain hubs.
WARNING: Do not use the USB port in hazardous locations.