Publication 1794-UM066A-EN-P - February 2012
Rack Optimized Discrete I/O 27
3. Select the 1756-EN2TR EtherNet/IP Bridge, and then click Create.
The New Module dialog opens.
4. Configure your 1756-EN2TR EtherNet/IP Bridge module through the
different tabs available.
Enter values for Name, IP Address, Slot, Electronic Keying, and Revision,
as follows:
5. Click OK to accept the configuration.
Add the FLEX I/O Adapter to the I/O Configuration
Next, you must add the 1794-AENTR adapter as a child of the local
1756-EN2TR module.
Name EN2TR
IP Address 130.130.130.2
Slot 0
Electronic Keying Compatible Module
Revision 3.1