Rockwell-automation 1794-AENTR_AENTRXT FLEX I/O Dual Port EtherNet/IP Instrukcja Użytkownika Strona 80

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 88
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 79
Publication 1794-UM066A-EN-P - February 2012
72 Adapter Web Dialogs
–Secondary Name Server
–Domain Name
For Ethernet Link Port 1 and Port 2, specify the following:
Autonegotiate Status
- Autonegotiate Speed and Duplex
- Force Speed and Duplex
Select Port Speed – 10 megabits, 100 megabits
Select Duplex Mode – Half Duplex, Full Duplex
7. From the Network Configuration page, click Apply Changes to save the
modified values.
Use the Device Services Page
To use the Services page to change the password for the Configuration web page
or disable the web server, click Device Services tab at the top of the page or panel
on the left.
The Device Services page opens.
From the Services page, make these entries.
Click the Enable box to change whether the web server runs after the
module is reset.
Change the password by typing a new value for New Password and
Confirm Password, noting the following:
The entry is case sensitive.
The default value is <blank>.
8. Click Apply Changes.
Przeglądanie stron 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 86 87 88

Komentarze do niniejszej Instrukcji

Brak uwag