Rockwell Automation Publication 520COM-UM003A-EN-E - June 2013 137
EtherNet/IP Objects Appendix C
Class Attributes
Instance Attributes
Attribute ID Access Rule Name Data Type Description
1 Get Revision UINT 1
2 Get Max Instance UINT Number of parameters
8 Get Parameter Class Descriptor WORD 0 = False, 1 = True
Bit 0 = Supports parameter instances
Bit 1 = Supports full attributes
Bit 2 = Must do NVS save command
Bit 3 = Parameters are stored in NVS
9 Get Configuration Assembly Instance UINT 0
10 Get Native Language USINT 1 = English
2 = French
3 = Spanish
4 = Italian
5 = German
6 = Japanese
7 = Portuguese
8 = Chinese Simplified
9 = Reserved
10 = Reserved
11 = Korean
12 = Polish
13 = Reserved
14 = Turkish
15 = Czech
Attribute ID Access Rule Name Data Type Description
1
(1)
Parameter Value
(2) (3)
2 Get Link Path Size USINT 0 = No link specified
n = The size of Attribute 3 in bytes
3GetLink Path
(4)
4 Get Descriptor WORD 0 = False, 1 = True
Bit 1 = Supports ENUMs
Bit 2 = Supports scaling
Bit 3 = Supports scaling links
Bit 4 = Read only
Bit 5 = Monitor
Bit 6 = Extended precision scaling
5 Get Data Type USINT 0xC2 = SINT (8-bits)
0xC3 = INT (16-bits)
0xC4 = DINT (32-bits)
0xC6 = USINT (8-bits)
0xC7 = UINT (16-bits)
0xCA = REAL (32-bits)
0xD2 = WORD (16-bits)
6 Get Data Size USINT
(3)
7 Get Parameter Name String SHORT_STRING
(3)
8 Get Units String SHORT_STRING
(3)
9 Get Help String SHORT_STRING
(3)
10 Get Minimum Value
(1) (3)
11 Get Maximum Value
(1) (3)
12 Get Default Value
(1) (3)
13 Get Scaling Multiplier UINT
(3)