Chapter 3 Embedded I/O
Configure the High-speed Counters
The Embedded HSC Counters Module Properties dialog box lets you
configure the high-speed counters for your application. Configuration of the
counters is typically completed by using RSLogix 5000 software during the
initial system configuration.
To configure your HSC Counters in RSLogix 5000 programming software,
complete these steps.
1. In the I/O Configuration tree, right-click slot 4, Embedded HSC
Counters and choose Properties.
2. Click the Input Configuration tab.
3. Specify the number of counters you are using.
4. If you are using the built-in low-pass input filters, use the pull-down
menus to specify your input filter times.