Message Packet Formats
Chapter 5
5-48
The STS and EXT STS bytes contain status and error code information.
For more information on these bytes, see the “Error Codes” section in this
document.
Read-Modify-Write
Use this command to take the contents of each location specified:
AND them with the appropriate AND mask.
OR them with the appropriate OR mask.
Restore them to their location, one word at a time.
The command parameters that follow the FNC byte in the example can be
repeated up to a length of 243 bytes.
TNSSTSCMD
0F
SRCDST FNC
26
AND
MASK
OR
MASK
PLC-5 SYSTEM
ADDRESS
Command
Format:
The PLC-5 system address must point to a word, and can be either a
logical binary address or a logical ASCII address with up to 51 bytes of
specification.
The AND and OR masks are two bytes each with the low byte first.
Reply
Format:
TNSSTSCMD
4F
SRCDST EXT
STS
The STS and EXT STS bytes contain status and error code information.
For more information on these bytes, see the “Error Codes” section in this
document.
Set Processor Mode
Use this command to set the Operating mode of the processor at the next
I/O scan. The Operating mode is set to the mode indicated in the flag byte
(shown below). A no privilege error is returned if the requestor does not