Rockwell Automation Publication 20COMM-UM015B-EN-P - July 2013 33
Configuring the Adapter Chapter 3
2. Set the value of Parameters 04 - [IP Addr Cfg 1] through 07 - [IP Addr
Cfg 4] to a unique IP address.
3. Reset the adapter; see Resetting the Adapter
on page 43.
The Network status indicator will be steady green or flashing green if
the IP address is correctly configured, and is connected to an operating
ethernet network.
Set a Subnet Mask Using Parameters
1. Verif y that Parameter 03 - [BOOTP/DHCP] is set to ‘0’ (Disabled).
2. Set the value of Parameters 08 - [Subnet Cfg 1] through 11 - [Subnet Cfg
4] to the desired value for the subnet mask.
3. Reset the adapter; see Resetting the Adapter
on page 43.
Set a Gateway Address Using Parameters
1. Verif y that Parameter 03 - [BOOTP] is set to ‘0’ (Disabled).
2. Set the value of Parameters 12 - [Gateway Cfg 1] through 15 - [Gateway
Cfg 4] to the IP address of the gateway device.
3. Reset the adapter; see Resetting the Adapter
on page 43.
Port 5 Device
20-COMM-ER
Parameter #: 04
IP Addr Cfg 1
0
0 <> 255
Default = 0.0.0.0 255.255.255.255
[IP Addr Cfg 1]
[IP Addr Cfg 2]
[IP Addr Cfg 3]
[IP Addr Cfg 4]
Port 5 Device
20-COMM-ER
Parameter #: 08
Subnet Cfg 1
0
0 <> 255
Default = 0.0.0.0
255.255.255.255
[Subnet Cfg 1]
[Subnet Cfg 2]
[Subnet Cfg 3]
[Subnet Cfg 4]
Port 5 Device
20-COMM-ER
Parameter #: 12
Gateway Cfg 1
0
0 <> 255
Default = 0.0.0.0
255.255.255.255
[Gateway Cfg
[Gateway Cfg 2]
[Gateway Cfg 3]
[Gateway Cfg 4]