2-10 Referencing the Motion Library
Control Attributes
long ControlGetFault(void);
Returns controller fault.
Valid fault returns are:
0 = Not faulted
4 = Motor overtemperature, thermostat
5 = IPM fault (overtemperature, overcurrent, short)
9 = Bus undervoltage
10 = Bus overvoltage
11 = Illegal hall state
14 = DeviceNet communications fault
17 = User-specified current fault
18 = Overspeed fault
19 = Excess position error
20 = Motor encoder state error
21 = Auxiliary encoder state error
22 = Motor thermal protection
23 = IPM thermal protection
24 = Excess velocity error
26 = User-specified velocity fault
29 = Encoder output frequency fault
39 = Self-sensing startup fault
58 = Excess CPU load