Rockwell-automation 20G PowerFlex 755 Drive Embedded EtherNet/IP Adapt Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 20G PowerFlex 755 Drive Embedded EtherNet/IP Adapt. Rockwell Automation 20G PowerFlex 755 Drive Embedded EtherNet/IP Adapter User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User Manual

PowerFlex 755 Drive Embedded EtherNet/IP AdapterFirmware Release Number 1.xxx (or later)User Manual

Strona 2 - Important User Information

10 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Preface Additional ResourcesThese documents contain additional information conce

Strona 3 - Information

100 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 6 Using Explicit Messaging ControlLogix Controller Example Scattered Re

Strona 4

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 101Using Explicit Messaging Chapter 6 ControlLogix Controller Example Ladder Logic

Strona 5 - Table of Contents

102 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 6 Using Explicit Messaging ControlLogix – Formatting a Message to Write

Strona 6

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 103Using Explicit Messaging Chapter 6 ControlLogix Controller Example Scattered Wr

Strona 7

104 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 6 Using Explicit Messaging ControlLogix Controller – Explanation of Req

Strona 8

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 105Using Explicit Messaging Chapter 6 When performing a Scattered Write to REAL da

Strona 9 - Rockwell Automation

106 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 6 Using Explicit Messaging Notes:

Strona 10 - Additional Resources

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 107 Chapter 7TroubleshootingThis chapter provides information for diagnosing and t

Strona 11 - Getting Started

108 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 7 Troubleshooting ENET Status IndicatorThis red/green bicolor LED indic

Strona 12 - Features

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 109Troubleshooting Chapter 7 Viewing Adapter Diagnostic ItemsIf you encounter unex

Strona 13 - Required Equipment

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 11 Chapter 1Getting StartedThe EtherNet/IP adapter, embedded on the Main Control B

Strona 14 - Chapter 1 Getting Started

110 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 7 Troubleshooting 27 DL To Net 01 Val The present value of respective D

Strona 15 - Safety Precautions

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 111Troubleshooting Chapter 7 Viewing and Clearing EventsThe adapter has an event q

Strona 16 - Quick Start

112 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 7 Troubleshooting Table 12 - Adapter EventsCode Event DescriptionAdapt

Strona 17 - Installing the Adapter

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 113 Chapter 8Viewing the Adapter Web PagesThis chapter provides instructions on ho

Strona 18 - Setting the IP Address

114 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 8 Viewing the Adapter Web Pages 2. In the Address box, type the IP addr

Strona 19

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 115Viewing the Adapter Web Pages Chapter 8 Navigation Pane on Adapter Web PagesThe

Strona 20 - Connecting the Adapter to

116 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 8 Viewing the Adapter Web Pages Process Display Pop-up Dialog BoxThe Pr

Strona 21 - Applying Power

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 117Viewing the Adapter Web Pages Chapter 8 TCP/IP Configuration Web PageThe TCP/IP

Strona 22

118 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 8 Viewing the Adapter Web Pages Configure E-mail Notification Web PageT

Strona 23

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 119Viewing the Adapter Web Pages Chapter 8 3. Type the following information in th

Strona 24 - Commissioning the Adapter

12 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 1 Getting Started FeaturesThe features of the embedded EtherNet/IP adapt

Strona 25 - Configuring the Adapter

120 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 8 Viewing the Adapter Web Pages Figure 37 shows an example email messag

Strona 26 - Setting the Adapter IP

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 121Viewing the Adapter Web Pages Chapter 8 Device Information PagesDevice informat

Strona 27 - Enabled 1

122 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 8 Viewing the Adapter Web Pages Figure 39 - Example of Port 0 (PowerFle

Strona 28

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 123Viewing the Adapter Web Pages Chapter 8 Figure 41 - Example of Port 0 (PowerFle

Strona 29

124 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 8 Viewing the Adapter Web Pages Notes:

Strona 30 - Set the Subnet Mask

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 125 Appendix ASpecificationsThis appendix presents the specifications for the adap

Strona 31 - Setting the Data Rate

126 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix A Specifications Notes:

Strona 32 - Peer-to-Peer Hierarchy

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 127 Appendix BAdapter ParametersThis appendix provides information about the adapt

Strona 33 - Enable Datalinks To Read Data

128 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix B Adapter Parameters Parameter ListParameterNo. Name and Description D

Strona 34

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 129Adapter Parameters Appendix B 35 [DLs To Net Act]Displays the number of drive-t

Strona 35 - 0<<2

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 13Getting Started Chapter 1 • Automatic Device Configuration (ADC), which is an ‘R

Strona 36 - Custom Peer I/O Configuration

130 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix B Adapter Parameters 46474849[Gateway Cfg 1][Gateway Cfg 2][Gateway Cf

Strona 37 - 10.00 Secs

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 131Adapter Parameters Appendix B 54 [Comm Flt Action]Sets the action that the adap

Strona 38 - Setting a Fault Action

132 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix B Adapter Parameters 56 [Peer Flt Action]Sets the action that the adap

Strona 39

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 133Adapter Parameters Appendix B 59 [Flt Cfg Ref]Sets the Reference data that is s

Strona 40 - Setting Web Access Control

134 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix B Adapter Parameters 78 [Logic Src Cfg]Controls which of the peer-to-d

Strona 41 - Defaults

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 135Adapter Parameters Appendix B 81828384[Fr Peer Addr 1][Fr Peer Addr 2][Fr Peer

Strona 42 - Using Parameters

136 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix B Adapter Parameters 90 [To Peer Skip]Sets the maximum time that an ad

Strona 43 - Firmware

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 137 Appendix CEtherNet/IP ObjectsThis appendix presents information about the Ethe

Strona 44

138 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Identity ObjectClass Code Services InstancesTh

Strona 45 - Configuring the I/O

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 139EtherNet/IP Objects Appendix C Assembly ObjectClass Code Services Instances

Strona 46 - ControlLogix Example

14 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 1 Getting Started ❑ Drive and embedded adapter configuration tool, such

Strona 47

140 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Register ObjectClass Code Services Instances

Strona 48

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 141EtherNet/IP Objects Appendix C PCCC ObjectClass Code Services InstancesSuppor

Strona 49

142 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Message Structure for Execute_DH+ The embedded

Strona 50 - Chapter 4 Configuring the I/O

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 143EtherNet/IP Objects Appendix C N-Files N-File DescriptionN42 This N-file lets

Strona 51

144 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects N-File DescriptionN150…N199 These N-files let y

Strona 52

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 145EtherNet/IP Objects Appendix C DPI Device Object Class Code Services Instance

Strona 53 - Configuring the I/O Chapter 4

146 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Class Attributes Attribute ID Access Rule Name

Strona 54

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 147EtherNet/IP Objects Appendix C Instance Attributes 20 Set Customer-Generated F

Strona 55

148 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects DPI Parameter ObjectClass Code To access ‘Host

Strona 56

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 149EtherNet/IP Objects Appendix C Instance Attributes Attribute ID Access Rule Na

Strona 57

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 15Getting Started Chapter 1 Safety PrecautionsPlease read the following safety pre

Strona 58

150 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects 16 Get Parameter Processing Error USINT 0 = No e

Strona 59

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 151EtherNet/IP Objects Appendix C Descriptor Attributes Bit Name Description0 Dat

Strona 60

152 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Extended Descriptor Attributes Bit Name Descrip

Strona 61

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 153EtherNet/IP Objects Appendix C Formulas for ConvertingDisplay Value = ((Interna

Strona 62

154 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects DPI Fault ObjectClass Code Products such as Pow

Strona 63

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 155EtherNet/IP Objects Appendix C Class Attributes Instance Attributes Attribute

Strona 64

156 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects DPI Alarm ObjectClass Code Products such as Pow

Strona 65

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 157EtherNet/IP Objects Appendix C Instance Attributes Attribute ID Access Rule Na

Strona 66 - ADC and Logix Memory

158 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects DPI Diagnostic ObjectClass Code Services Insta

Strona 67

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 159EtherNet/IP Objects Appendix C Instance Attributes Attribute ID Access Rule Na

Strona 68

16 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 1 Getting Started Quick StartThis section is provided to help experience

Strona 69

160 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects DPI Time ObjectClass Code Services InstancesTh

Strona 70

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 161EtherNet/IP Objects Appendix C Instance Attributes 8 Get Active Time Zone Data

Strona 71 - Monitoring ADC Progress

162 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Host DPI Parameter ObjectClass Code To access ‘

Strona 72

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 163EtherNet/IP Objects Appendix C Instance Attributes Attribute ID Access Rule Na

Strona 73

164 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects 16 Get Parameter Processing Error USINT 0 = No e

Strona 74

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 165EtherNet/IP Objects Appendix C Descriptor Attributes Bit Name Description0 Dat

Strona 75

166 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Extended Descriptor Attributes Bit Name Descrip

Strona 76

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 167EtherNet/IP Objects Appendix C Formulas for ConvertingDisplay Value = ((Interna

Strona 77

168 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects TCP/IP Interface ObjectClass Code Services Ins

Strona 78

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 169EtherNet/IP Objects Appendix C 4 Get Physical Link Object STRUCT of:UINTPadded

Strona 79 - Using the I/O

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 17 Chapter 2Installing the AdapterSince the EtherNet/IP adapter is embedded on the

Strona 80 - ControlLogix Controller I/O

170 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Ethernet Link ObjectClass Code Services Instan

Strona 81 - Using Reference/Feedback

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 171EtherNet/IP Objects Appendix C 5 Get Media Counters STRUCT of:UDINTUDINTUDINTUD

Strona 82 - Using Datalinks

172 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix C EtherNet/IP Objects Notes:

Strona 83 - Program Information

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 173 Appendix DLogic Command/Status Words: PowerFlex 750-Series DrivesThis appendix

Strona 84 - ControlLogix Controller

174 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix D Logic Command/Status Words: PowerFlex 750-Series Drives Logic Status

Strona 85 - Using the I/O Chapter 5

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 175 Appendix EHistory of ChangesThis appendix summarizes the revisions to this man

Strona 86 - Versions

176 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Appendix E History of Changes 750COM-UM001C-EN-P, November 2011 750COM-UM001B-E

Strona 87 - Program

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 177 GlossaryThe following terms and abbreviations are used throughout this manual.

Strona 88 - Program Tags

178 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Glossary Controller A controller, also called programmable logic controller, is

Strona 89 - Example Datalink Data

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 179Glossary EtherNet/IP Network EtherNet/IP (Industrial Protocol) is an open produ

Strona 90 - Generic Profile

18 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 2 Installing the Adapter consumer model. Historically, most switches hav

Strona 91 - Using Explicit Messaging

180 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Glossary Idle Action An idle action determines how the adapter and connected dr

Strona 92 - About Explicit Messaging

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 181Glossary Master-Slave Hierarchy An adapter configured for a master-slave hierar

Strona 93

182 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Glossary Stop Action When communication is disrupted (for example, a cable is d

Strona 94 - Examples

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 183Glossary Zero Data When communication is disrupted (for example, a cable is dis

Strona 95

184 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Glossary Notes:

Strona 96 - Single Parameter

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 185 IndexAadapterapplying power 21commissioning 24compatible products 13components

Strona 97

186 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Index Ethernetcable 20connector on adapter 11switch 20Ethernet Link object 170E

Strona 98

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 187Index NNet Addr Src parameter 129Net Rate Act parameter 130Net Rate Cfg paramet

Strona 99

188 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Index website forBOOTP/DHCP server 177Connected Components Workbench software 1

Strona 101 - Multiple Parameters

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 19Installing the Adapter Chapter 2 •Adapter Parameters — Use adapter parameters wh

Strona 102

Publication 750COM-UM001E-EN-P - October 2013 Supersedes Publication 750COM-UM001D-EN-P - February 2012 Copyright © 2013 Rockwell Automation, Inc. Al

Strona 103

Important User InformationRead this document and the documents listed in the additional resources section about installation, configuration, and opera

Strona 104

20 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 2 Installing the Adapter The switch settings can be verified by viewing

Strona 105 - Request (Source Data) array

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 21Installing the Adapter Chapter 2 Applying PowerInstall the drive cover, and appl

Strona 106

22 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 2 Installing the Adapter Table 1 - Drive and Adapter Start-Up Status Ind

Strona 107 - Troubleshooting

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 23Installing the Adapter Chapter 2 2. Use drive Parameter 545 - [Speed Ref A Sel]

Strona 108 - LINK Status Indicator

24 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 2 Installing the Adapter Commissioning the AdapterTo commission the embe

Strona 109 - Viewing Adapter Diagnostic

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 25 Chapter 3Configuring the AdapterThis chapter provides instructions and informat

Strona 110

26 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter Using the PowerFlex 20-HIM-A6 or 20-HIM-C6S HI

Strona 111 - Viewing and Clearing Events

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 27Configuring the Adapter Chapter 3 1. Verif y that Parameter 36 - [BOOTP] is set

Strona 112 - Table 12 - Adapter Events

28 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter To properly configure devices on your EtherNe

Strona 113 - Viewing the Adapter Web Pages

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 29Configuring the Adapter Chapter 3 7. In the BOOTP/DHCP Request History list, eit

Strona 114

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 3 Summary of ChangesThis manual contains new and updated information.New and Upd

Strona 115

30 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter Using Adapter ParametersBy default, the adapte

Strona 116 - Dialog Box

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 31Configuring the Adapter Chapter 3 2. Set the value of Parameters 42 - [Subnet Cf

Strona 117 - TCP/IP Configuration Web

32 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter 2. Reset the adapter by power cycling the driv

Strona 118 - Web Page

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 33Configuring the Adapter Chapter 3 peripheral receive the values from the network

Strona 119

34 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter respective controller example sections in Chap

Strona 120

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 35Configuring the Adapter Chapter 3 Simple Peer I/O ConfigurationThe most common u

Strona 121 - Device Information Pages

36 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter Custom Peer I/O ConfigurationPeer I/O also all

Strona 122

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 37Configuring the Adapter Chapter 3 4. Set Parameter 80 - [Fr Peer Timeout] to a t

Strona 123 - EtherNet/IP adapter)

38 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter For example, if Parameter 76 - [DLs Fr Peer Cf

Strona 124

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 39Configuring the Adapter Chapter 3 Changing the Fault ActionSet the values of Pa

Strona 125 - Specifications

4 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Summary of Changes Notes:

Strona 126 - Appendix A Specifications

40 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter occurs. You must set these parameters to value

Strona 127 - Adapter Parameters

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 41Configuring the Adapter Chapter 3 Bit 0 is the right-most bit. In the example ab

Strona 128 - Parameter List

42 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter 7. Press the (Enter) key again to display th

Strona 129

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 43Configuring the Adapter Chapter 3 Updating the Adapter FirmwareThe adapter firmw

Strona 130

44 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 3 Configuring the Adapter Notes:

Strona 131

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 45 Chapter 4Configuring the I/OThis chapter provides instructions on how to config

Strona 132

46 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O The Configure Drivers dialog box reappears with th

Strona 133

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 47Configuring the I/O Chapter 4 Figure 6 - Example ControlLogix Controller EtherNe

Strona 134

48 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 4. Expand the Communications group to display all

Strona 135

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 49Configuring the I/O Chapter 4 10. Click OK.The bridge is now configured for the

Strona 136

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 5 Table of ContentsPrefaceConventions Used in This Manual . . . . . . . . . . . .

Strona 137 - EtherNet/IP Objects

50 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O • Drive Add-on Profiles, version 2.01 or later, en

Strona 138 - Identity Object

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 51Configuring the I/O Chapter 4 The drive’s New Module dialog box appears. 4. On

Strona 139 - Assembly Object

52 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 6. In the Module Definition dialog box, edit the f

Strona 140 - Register Object

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 53Configuring the I/O Chapter 4 parameters. The procedure to configure the Datalin

Strona 141 - PCCC Object

54 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 8. Click the Connection tab. 9. In the ‘Requested

Strona 142

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 55Configuring the I/O Chapter 4 12. Click Set to save the Port Configuration infor

Strona 143 - N-Files

56 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O Figure 8 - Controller Output Tags Save the I/O Co

Strona 144

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 57Configuring the I/O Chapter 4 2. Click Download to download the configuration to

Strona 145 - DPI Device Object

58 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 2. Click the Drive tab. 3. Click Connect to Drive

Strona 146 - Class Attributes

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 59Configuring the I/O Chapter 4 6. To match the Datalinks in the drive to the proj

Strona 147 - Instance Attributes

6 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Table of Contents Chapter 5Using the I/OAbout I/O Messaging . . . . . . . . . .

Strona 148 - DPI Parameter Object

60 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O ADC can also work in tandem with Firmware Supervi

Strona 149

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 61Configuring the I/O Chapter 4 • When converting RSLogix 5000 projects, version 1

Strona 150 - Extended DPI descriptor

62 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O Configure a PowerFlex 755 Drive for ADCADC is conf

Strona 151 - Descriptor Attributes

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 63Configuring the I/O Chapter 4 There are three Electronic Keying choices availabl

Strona 152

64 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 6. Click the Port Properties icon to open the Pr

Strona 153 - Object Specific Services

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 65Configuring the I/O Chapter 4 11. Click the ADC icon to open the ADC Settings

Strona 154 - DPI Fault Object

66 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 14. Save your RSLogix 5000 project and download th

Strona 155

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 67Configuring the I/O Chapter 4 • A PowerFlex 755 drive with four option modules,

Strona 156 - DPI Alarm Object

68 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 7. On the Controller Properties dialog box, click

Strona 157

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 69Configuring the I/O Chapter 4 11. RSLogix 5000 software will go to the Offline s

Strona 158 - DPI Diagnostic Object

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 7Table of Contents Appendix CEtherNet/IP ObjectsSupported Data Types . . . . . . .

Strona 159

70 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O Note that after setting DeviceLogix Parameter 53 t

Strona 160 - DPI Time Object

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 71Configuring the I/O Chapter 4 1. Inhibit the drive’s connection—or disconnect th

Strona 161

72 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O • If a configuration signature for the drive/perip

Strona 162 - Host DPI Parameter Object

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 73Configuring the I/O Chapter 4 Examples of potential issues/solutions are shown i

Strona 163

74 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 2. Expand the Communications group to display all

Strona 164

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 75Configuring the I/O Chapter 4 6. Under Connection Parameters, edit the following

Strona 165

76 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 8. Click the Connection tab. 9. In the ‘Requested

Strona 166

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 77Configuring the I/O Chapter 4 Figure 9 - Input Image Controller Tags Figure 10

Strona 167

78 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 4 Configuring the I/O 1. From the Communications menu in the RSLogix 500

Strona 168 - TCP/IP Interface Object

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 79 Chapter 5Using the I/OThis chapter provides information and examples that expla

Strona 169

8 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Table of Contents

Strona 170 - Ethernet Link Object

80 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 5 Using the I/O Understanding the ControlLogix Controller I/O ImageThe t

Strona 171

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 81Using the I/O Chapter 5 Using Logic Command/StatusThe Logic Command is a 32-bit

Strona 172

82 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 5 Using the I/O When Parameter 300 - [Speed Units] is set to RPM, the ot

Strona 173 - 750-Series Drives

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 83Using the I/O Chapter 5 drive, the drive does not allow a reset to defaults, con

Strona 174

84 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 5 Using the I/O ControlLogix Controller ExampleThis section includes inf

Strona 175 - History of Changes

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 85Using the I/O Chapter 5 Figure 12 - ControlLogix Controller Example Ladder Logic

Strona 176

86 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 5 Using the I/O Creating Ladder Logic Using the RSLogix 5000 Generic Pro

Strona 177 - Glossary

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 87Using the I/O Chapter 5 Controller TagsWhen you add the adapter and drive to the

Strona 178

88 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 5 Using the I/O Program TagsTo use the Controller tags that are automati

Strona 179

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 89Using the I/O Chapter 5 Figure 17 - ControlLogix Controller Example Ladder Logic

Strona 180

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 9 PrefaceThis manual provides information about the EtherNet/IP adapter embedded o

Strona 181

90 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 5 Using the I/O Figure 18 - ControlLogix Controller Example Datalinks fo

Strona 182

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 91 Chapter 6Using Explicit MessagingThis chapter provides information and examples

Strona 183

92 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 6 Using Explicit Messaging About Explicit MessagingExplicit Messaging is

Strona 184

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 93Using Explicit Messaging Chapter 6 Performing Explicit MessagingThere are five b

Strona 185

94 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 6 Using Explicit Messaging ControlLogix Controller ExamplesFor supported

Strona 186

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 95Using Explicit Messaging Chapter 6 ControlLogix – Formatting a Message to Read a

Strona 187

96 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 6 Using Explicit Messaging ControlLogix Controller Example Ladder Logic

Strona 188

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 97Using Explicit Messaging Chapter 6 ControlLogix – Formatting a Message to Write

Strona 189

98 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013Chapter 6 Using Explicit Messaging ControlLogix Controller Example Ladder Logic

Strona 190 - Documentation Feedback

Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013 99Using Explicit Messaging Chapter 6 ControlLogix – Formatting a Message to Read M

Komentarze do niniejszej Instrukcji

Brak uwag