Publication 2092-RM001A-EN-P — March 2005
2-36 Command Reference
Group 6 Parameters
[Pr – 6.00] Analog Velocity Command Offset
[Pr – 6.01] Analog Current Command Offset
[Pr – 6.04] Main Velocity Regulator D Gain
[Pr – 6.05] Velocity Error Filter
[Pr – 6.06] Fault Detail Sampling Period
Ultraware Name Velocity Command Offset
Range: -10000 to 10000
Default: 0
Units: 0.1 mV
Operating Mode: Analog Velocity Command
Range: -10000 to 10000
Default: 0
Units: 0.1 mV
Operating Mode: Analog Velocity Command
Range: 0 to 1000
Default: 0
Units: -
Operating Mode:
Follower, Analog Velocity, Preset
Ultraware Name:
Calibration: Error Filter Bandwidth
Range: 0 to 2500
Default: 30
Units: Hz
Operating Mode: Follower, Analog Velocity, Preset
Ultraware Name:
Fault Detail Setup: Sample Period
Range: 1 to 99
Default: 5
Units: 0.2 msec