Rockwell Automation Publication 520COM-UM001B-EN-E - March 2013 115
Troubleshooting Chapter 8
10 Slave Detected The adapter detected that the slave is connected.
11 Slave Removed The adapter detected that the slave was disconnected.
12 Slave Logon The adapter has established communications with the slave.
13 Slave Timeout The adapter has lost communications with the slave.
14 Slave Brand Flt The brand of the slave is different from the adapter.
15 Host 0 Logon The adapter has established communications with host 0.
16 Host 1 Logon The adapter has established communications with host 1.
17 Host 2 Logon The adapter has established communications with host 2.
18 Host 3 Logon The adapter has established communications with host 3.
19 Host 4 Logon The adapter has established communications with host 4.
20 Host 0 Timeout The adapter has lost communications with host 0.
21 Host 1 Timeout The adapter has lost communications with host 1.
22 Host 2 Timeout The adapter has lost communications with host 2.
23 Host 3 Timeout The adapter has lost communications with host 3.
24 Host 4 Timeout The adapter has lost communications with host 4.
25 Host 0 Brand Flt The brand of host 0 is different from the adapter.
26 Host 1 Brand Flt The brand of host 1 is different from the adapter.
27 Host 2 Brand Flt The brand of host 2 is different from the adapter.
28 Host 3 Brand Flt The brand of host 3 is different from the adapter.
29 Host 4 Brand Flt The brand of host 4 is different from the adapter.
Network Events
40 EN Link Up A network link was available for the adapter.
41 EN Link Down The network link was removed from the adapter.
42 Dup IP Addr The adapter uses the same IP address as another device on the network.
43 EN Open An I/O connection from the network to the adapter has been opened.
44 EN Close An I/O connection from the network to the adapter was closed.
45 EN Timeout An I/O connection from the network to the adapter has timed out.
46 EN Comm Flt An I/O connection from the network to the adapter.
47 EN Idle Flt The adapter received “idle” packets from the network.
48 PCCC IO Open The adapter has begun receiving PCCC Control messages (the PCCC Control Timeout
was previously set to a non-zero value).
49 PCCC IO Close The device sending PCCC Control messages to the adapter has set the PCCC Control
Timeout to zero.
50 PCCC IO Time Flt The adapter has not received a PCCC Control message for longer than the PCCC Control
Timeout.
51 EN Sent Reset The adapter received a reset from the network.
52 Msg Ctrl Open The adapter has begun receiving Client-Server-Control messages (the Client-Server-
Control Timeout was previously set to a non-zero value).
53 Msg Ctrl Close The device sending Client-Server-Control messages to the adapter has set the Client-
Server-Control Timeout to zero.
54 Msg Ctrl Timeout The adapter has not received a Client-Server-Control message for longer than the
established timeout period.
Adapter Specific Events
60 BOOTP Response The module received a response to its BOOTP request.
61 E-mail Failed The module encountered an error attempting to send a requested e-mail message.
Adapter Events
Code Event Description