Chapter 3
Wiring and Installation
3–9
Figure 3.2
Depth Dimensions in Inches (mm)
800A and Sealed Modules
6.88
(174.75) Max.
.44 (11.18)
Max Height of Buttons
.31
(7.87)
.12 (3.05)
Max Thickness
2. Drill 4 (or 6) 0.312” (7.92mm) diameter holes for the top and bottom
mounting brackets.
3. Slide the Module through the opening. The mounting tabs help seat the
Module against an 1/16” (1.6mm) to 1/8” (3.2mm) thick enclosure.
4. To complete the mechanical installation, apply the mounting brackets and
tighten all the captive knurled thumbscrews. Figure 3.3 shows the
location of these screws. NOTE: Your unit may not have a mounting
bracket and thumbscrews. In that case, tighten the #10-32 nuts that are
provided to complete the installation.
Figure 3.3
Mounting Bracket Thumbscrews
Thumbscrews
Mounting Bracket