A–B
5
Chapter
5–1
Maintenance and Troubleshooting
This chapter contains the following sections.
Section Page
Preventive Maintenance 5–1
Using the Fault Indicator 5–2
Using the COMM Indicator 5–3
Using the Push-to-Test Button 5–4
Removing the Back Panel of 800T/800H Push Button Modules 5–5
Basic Troubleshooting Questions 5–6
The best maintenance technique is preventive maintenance. Observe the
following guidelines to minimize malfunctions:
Once a month, use the push-to-test button located on the front of the Push
Button Module.
Prevent accumulation of dust and dirt by:
Installing in a NEMA Type 12/13 or 4/4X enclosure
Keeping enclosure clean
Keeping enclosure doors closed
Avoid hot spots by:
Maintaining minimum spacing
Not storing unnecessary articles in enclosure
Periodically check for loose connections.
!
ATTENTION: To avoid shock hazard, remove incoming power
before checking connections.
Avoid electrical noise by:
Following the electrical guidelines discussed in Chapter 6
Keeping enclosure doors closed