Chapter 3
Wiring and Installation
3–15
To install a 16 Push Button 800T/H Module:
1. Cut an opening in the panel approximately 14 inches (355.60mm) W x 15
inches (381.0mm) H. See Figure 3.9
2. Drill ten 0.22 inch diameter holes for the mounting studs.
3. Slide the module through the opening.
4. Fasten the module in place with the enclosed locking nuts.
Figure 3.9
Mounting Dimensions in Inches (mm)
16 Button 800T/H Modules
#10-32 Mtg. Studs
(14 Places)
0.25 (6.4)
Gasket
1
.50 (
3
8.
1
)
Max. 800T
0.12
(3.2)
0.62
(15.9)
Wire Loop
1.00
(25.4)
1.00
(25.4)
.50
(12.7)
.87
(22.1)
.87
(22.1)
.50
(12.7)
.50
(12.7)
3.75
(95.3)
6.50
(165.1)
16.75
(419.1)
15.75
(393.7)
6.50
(165.1)
6.50
(165.1)
14.00
(355.6)
15.00
(381.0)
PANEL
CUTOUT
.22 (5.5) Dia.
(14 Places)
8.00
(203.2)
14.50
(368.3)
8.49
(215.5)