Rockwell-automation 25-COMM-P PowerFlex PROFIBUS DPV1 Adapter Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 25-COMM-P PowerFlex PROFIBUS DPV1 Adapter. Rockwell Automation 25-COMM-P PowerFlex PROFIBUS DPV1 Adapter User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User Manual

PowerFlex 25-COMM-P PROFIBUS DPV1 AdapterUser Manual

Strona 2 - Important User Information

10 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 1 Getting StartedSafety PrecautionsPlease read the following safety preca

Strona 3 - Table of Contents

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 11Getting Started Chapter 1Quick StartThis section is provided to help experienced

Strona 4

12 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 1 Getting StartedNotes:

Strona 5 - Overview

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 13Chapter 2Installing the AdapterThis chapter provides instructions for installing

Strona 6 - Preface Overview

14 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 2 Installing the AdapterSetting the Endianness and Node Address Using the

Strona 7 - Getting Started

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 15Installing the Adapter Chapter 2Node Address Switch SettingsDescription of Node A

Strona 8 - Understanding Parameter

16 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 2 Installing the Adaptera. Press and hold down the catch on both sides of

Strona 9 - Required Equipment

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 17Installing the Adapter Chapter 24. Insert the interface connector for the adapter

Strona 10 - Safety Precautions

18 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 2 Installing the Adapter5. Align the Communication card-Drive header on t

Strona 11 - Quick Start

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 19Installing the Adapter Chapter 2PROFIBUS Connector4. Connect the PROFIBUS cable t

Strona 12 - Chapter 1 Getting Started

Important User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Strona 13 - Installing the Adapter

20 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 2 Installing the AdapterWiring Example6. Connect the other end of the PRO

Strona 14

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 21Installing the Adapter Chapter 2Drive and Adapter Status IndicatorsConfiguring/Ve

Strona 15 - Connecting the Adapter to

22 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 2 Installing the AdapterFor more information on how to set different comb

Strona 16

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 23Chapter 3Configuring the AdapterThis chapter provides instructions and informatio

Strona 17

24 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 3 Configuring the AdapterStep Key(s) Example Display1. When power is appl

Strona 18

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 25Configuring the Adapter Chapter 3Using the PowerFlex 4-Class HIM to Access Parame

Strona 19 - Network Wiring Diagram

26 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 3 Configuring the AdapterUsing Master-Slave Hierarchy (Optional)This proc

Strona 20 - PROFIBUS

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 27Configuring the Adapter Chapter 3Enabling Datalinks To Read DataHost parameters C

Strona 21 - EtherNet/IP

28 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 3 Configuring the AdapterChanging the Fault ActionSet the values of Devic

Strona 22

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 29Configuring the Adapter Chapter 3When you enter 1 “Reset Module”, the adapter wil

Strona 23 - Configuring the Adapter

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 3Table of ContentsPrefaceOverviewRecommended Documentation . . . . . . . . . . . .

Strona 24

30 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 3 Configuring the AdapterTo obtain a firmware update for this adapter, go

Strona 25 - Setting the Node Address

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 31Chapter 4Configuring the PROFIBUS MasterPROFIBUS masters are available from sever

Strona 26 - (Optional)

32 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 4 Configuring the PROFIBUS MasterConfiguring the MVI69-PDPMV1 PROFIBUS DP

Strona 27 - Setting a Fault Action

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 33Configuring the PROFIBUS Master Chapter 43. For the selected MVI69-PDPMV1 module,

Strona 28 - Resetting the Adapter

34 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 4 Configuring the PROFIBUS Master7. After choosing 1769 E3xE, click Confi

Strona 29

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 35Configuring the PROFIBUS Master Chapter 41. From the Tools menu, choose Install n

Strona 30

36 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 4 Configuring the PROFIBUS MasterConfiguring the Adapter as a SlaveFollow

Strona 31 - Example Network

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 37Configuring the PROFIBUS Master Chapter 44. Drag the input and output parameters

Strona 32 - PDPMV1 PROFIBUS DPV1

38 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 4 Configuring the PROFIBUS Master5. Double-click the Slave icon to view t

Strona 33

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 39Configuring the PROFIBUS Master Chapter 47. Click on the Parameter assignment tab

Strona 34 - Installing GSD Files

4 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Table of ContentsUsing Reference/Feedback . . . . . . . . . . . . . . . . . . . .

Strona 35

40 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 4 Configuring the PROFIBUS Master2. From the Select Connection Type pull-

Strona 36 - Configuring the Adapter as a

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 41Chapter 5Using the I/OThis chapter provides information and examples that explain

Strona 37

42 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 5 Using the I/OUnderstanding the I/O ImageThe terms input and output are

Strona 38

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 43Using the I/O Chapter 5P044 [Maximum Freq]. PowerFlex 520-Series Drive Example Sp

Strona 39

44 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 5 Using the I/Omakeup of the I/O connection in a running system. The I/O

Strona 40

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 45Using the I/O Chapter 5Output Mapping in the MVI69-PDPMV1The input and output dat

Strona 41 - Using the I/O

46 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 5 Using the I/ONotes:

Strona 42 - Using Reference/Feedback

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 47Chapter 6Using Acyclic MessagingThis chapter provides information and examples th

Strona 43 - Using Datalinks

48 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 6 Using Acyclic MessagingPROFIBUS Slot and Index for Drive and Adapter Pa

Strona 44 - I/O Communication

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 49Using Acyclic Messaging Chapter 6Acyclic Messaging for DPV1 ClassThe 25-COMM-P ad

Strona 45 - Online Slave Properties

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 5PrefaceOverviewRecommended DocumentationAll the recommended documentation listed i

Strona 46 - Chapter 5 Using the I/O

50 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 6 Using Acyclic MessagingClass 1 Acyclic Read for Host Parameter 1 [Outpu

Strona 47 - Using Acyclic Messaging

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 51Using Acyclic Messaging Chapter 6Class 1 Acyclic Read Response Data for Host Para

Strona 48

52 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 6 Using Acyclic MessagingWrite Example for Host Parameter 41 [Accel Time

Strona 49 - Acyclic Messaging Examples

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 53Using Acyclic Messaging Chapter 6Class 1 Acyclic Write for Host Parameter 41 [Acc

Strona 50

54 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 6 Using Acyclic MessagingClass 1 Acyclic Write Response Data for Host Par

Strona 51 - Acyclic Read operations

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 55Chapter 7Using Multi-Drive ModeThis chapter provides instructions on how to confi

Strona 52

56 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 7 Using Multi-Drive ModeMulti-Drive Mode Example for NetworkBenefits of M

Strona 53

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 57Using Multi-Drive Mode Chapter 7• Since the RS-485 ports are used for daisy-chain

Strona 54

58 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 7 Using Multi-Drive ModeMulti-Drive Example of I/O ImageNote: If a daisy-

Strona 55 - Using Multi-Drive Mode

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 59Using Multi-Drive Mode Chapter 7The following Multi-drive parameters must be set

Strona 56

6 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Preface OverviewThe following conventions are used throughout this manual:• Para

Strona 57 - System Wiring

60 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 7 Using Multi-Drive ModeMulti-Drive Ladder Logic Program for Generic Prof

Strona 58

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 61Using Multi-Drive Mode Chapter 7CompactLogix Controller ExampleThe following comm

Strona 59

62 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 7 Using Multi-Drive ModeMain RoutineDrive 0...4 Control RoutinesThe follo

Strona 60 - Program for Generic Profile

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 63Using Multi-Drive Mode Chapter 7Drive 0 Control Routine05(End)Copy FileSourceDest

Strona 61 - CompactLogix Controller

64 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 7 Using Multi-Drive ModeDrive 1 Control Routine05(End)Copy FileSourceDest

Strona 62 - Drive 0...4 Control Routines

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 65Using Multi-Drive Mode Chapter 7Drive 2 Control Routine05(End)Copy FileSourceDest

Strona 63 - Drive 0 Control Routine

66 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 7 Using Multi-Drive ModeDrive 3 Control Routine05(End)Copy FileSourceDest

Strona 64 - Drive 1 Control Routine

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 67Using Multi-Drive Mode Chapter 7Drive 4 Control RoutineMulti-Drive Mode Acyclic M

Strona 65 - Drive 2 Control Routine

68 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 7 Using Multi-Drive ModeFor example, to access [Accel Time 1] (parameter

Strona 66 - Drive 3 Control Routine

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 69Chapter 8TroubleshootingThis chapter provides information for diagnosing and trou

Strona 67 - on page 48 to

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 7Chapter 1Getting StartedThe 25-COMM-P adapter is intended for installation into aP

Strona 68 - Additional Information

70 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 8 TroubleshootingPORT Status IndicatorThis red/green bicolor LED indicate

Strona 69 - Troubleshooting

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 71Troubleshooting Chapter 8Viewing Adapter Diagnostic ItemsIf you encounter unexpec

Strona 70 - NET A Status Indicator

72 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 8 TroubleshootingResetting the adapter to defaults has no effect on the e

Strona 71 - Viewing and Clearing Events

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 73Troubleshooting Chapter 863 Net Clear Cmd The adapter received a PROFIBUS “Clear

Strona 72 - Adapter Events

74 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 8 TroubleshootingNotes:

Strona 73

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 75Appendix ASpecificationsAppendix A presents the specifications for the adapter.Co

Strona 74 - Chapter 8 Troubleshooting

76 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Appendix A SpecificationsNotes:

Strona 75 - Specifications

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 77Appendix BAdapter ParametersAppendix B provides information about the adapter par

Strona 76 - Appendix A Specifications

78 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Appendix B Adapter Parameters08 [Net Rate Actual]Displays the actual speed (bps)

Strona 77 - Adapter Parameters

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 79Adapter Parameters Appendix B12 [Idle Flt Action]Sets the action that the adapter

Strona 78

8 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Chapter 1 Getting StartedFeaturesThe features of the adapter include:• Mounting on

Strona 79

80 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Appendix B Adapter Parameters19 [Reset Module]No action if set to 0 “Ready”. Rese

Strona 80

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 81Appendix CLogic Command/Status Words: PowerFlex 520-Series DrivesAppendix C prese

Strona 81 - Series Drives

82 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Appendix C Logic Command/Status Words: PowerFlex 520-Series DrivesPosition Bit De

Strona 82 - 1 = Travel Disable

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 83Logic Command/Status Words: PowerFlex 520-Series Drives Appendix CPosition Bit De

Strona 83 - Position Bit Definitions

84 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Appendix C Logic Command/Status Words: PowerFlex 520-Series DrivesNotes:

Strona 84

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 85GlossaryThe following terms and abbreviations are used throughout this manual. Fo

Strona 85 - Glossary

86 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013GlossaryData Rate The speed at which data is transferred on the PROFIBUS network.

Strona 86

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 87 GlossaryI/O Data I/O data, sometimes called “implicit messages” or “input/output

Strona 87 - Glossary

88 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013GlossaryPROFIBUS Network A PROFIBUS network uses RS485 to connect devices such as

Strona 88

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 89 GlossaryUpdate The process of updating firmware in a device. The adapter can be

Strona 89

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 9Getting Started Chapter 1Yo u c a n v i e w a dap te r Device parameters and H

Strona 90

90 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013GlossaryNotes:

Strona 91

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013 91IndexAacyclic messagingabout, 47definition, 85multi-drive mode, 67adapterapplying

Strona 92

92 Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013Indexnode addressdefinition, 87setting with a parameter, 25setting with switches,

Strona 94 - Documentation Feedback

Publication 520COM-UM004A-EN-E - November 2013Copyright © 2013 Rockwell Automation, Inc. All rights reserved.Rockwell Automation SupportRockwell Autom

Komentarze do niniejszej Instrukcji

Brak uwag