Publication 1760-UM003A-EN-P - September 2005
7-38 Pico GFX Control Commands
Text output function block: D01 – D32
Table 6.134 Telegram Structure
Byte Meaning Value (hex), sent by
Master Slav
e
Master Slave
Attribute ID
Read 92
Write B2
0 Response:
Read successful C2
Write successful C1
Command rejected C0
0 1 Type 19 19
1 2 Instance 01 – 20 01 – 20
2 3 Index Table 6.135 Table 6.135
3 – 6 4 – 7 Data 1 – 4
Read operation 00 depending on
index,Table 6.136
Write operation depending on index,
Table 6.136
00
Table 6.135 Operand overview
Index
(hex)
Operand read write
00 Bit IO, Table 6.136 x
01 Mode/Parameter
02 Text line 1, column 1 - 4 x
03 Text line 1, column 5 - 8 x
04 Text line 1, column 9 - 12 x
05 Text line 1, column 13 - 16 x
06 Text line 2, column 1 - 4 x
07 Text line 2, column 5 - 8 x
08 Text line 2, column 9 - 12 x
09 Text line 2, column 13 - 16 x
10 Text line 3, column 1 - 4 x