Pico GFX Control Commands 7-59
Synchronize clock function block: SC01
Table 6.183 Index 0 – Bit IO
Bit76543210
FB input Data 1
EN
(1)
(1) Activates the function block on status 1.
FB output Data 3 –––––––
E1
(2)
(2) Status 1 if below the minimum on duration or minimum off duration
Table 6.184 Telegram Structure
Byte Meaning Value (hex), sent by
Master Slave Master Slave
Attribute ID: Read 92
0 Response:
Read successful C2
Command rejected C0
0 1 Type 20 20
1 2 Instance 01 01
2 3 Index Table 6.185 Table 6.185
3 – 6 4 – 7 Data 1 – 4 00 depending on
index,Table 6.186
Table 6.185 Operand overview
Index
(hex)
Operand read write
00 Bit IO, Table 6.186 x
01 Mode/Parameter
Table 6.186 Index 0 – Bit IO
Bit76543 2 1 0
FB input Data 1
T
(1)
FB output Data 3
Q1
(2)