Publication 1760-UM003A-EN-P - September 2005
Pico GFX Control Commands 7-57
1 2 Instance 01 – 20 01 – 20
2 3 Index Table 6.179 Table 6.179
3 – 6 4 – 7 Data 1 – 4 00 depending on
index,Table 6.180
Table 6.179 Operand overview
Index
(hex)
Operand read write
00 Bit IO, Table 6.180 x
01 Mode/Parameter
02 Input value: Setpoint that it
transmitted to the NET network
I1 x
TIP
The data for index 2 is transferred as a 32-bit value in
Intel format (Data 1 – Low Byte to Data 4 – High
Byte).
Table 6.180 Index 0 – Bit IO
Bit76543 2 1 0
FB input Data 1
T
(1)
(1) Trigger coil. The value is provided on the NET if the coil is triggered (with a rising edge).
FB output Data 3
Q1
(2)
(2) Status 1 if the trigger coil PT..T_ is also 1.
Table 6.178 Telegram Structure
Byte Meaning Value (hex), sent by
Master Slave Master Slave