Pico GFX Control Commands 7-51
Value scaling: LS01 – LS32
Table 6.164 Resulting Telegram
Byte Meaning Value (hex), sent by
Master Slave
0 Attribute ID: Write B2
Response: Write
successful
–C1
1Type 1D 1D
2 Instance 0E 0E
3 Index 02 02
4 Data 1 8E 00
5 Data 2 06 00
6 Data 3 43 00
7 Data 4 19 00
Table 6.165 Telegram Structure
Byte Meaning Value (hex), sent by
Master Slave Master Slave
Attribute ID
Read 92
Write B2
0 Response:
Read successful C2
Write successful C1
Command rejected C0
0 1 Type 29 29
1 2 Instance 01 – 20 01 – 20
2 3 Index Table 6.166 Table 6.166
3 – 6 4 – 7 Data 1 – 4
Read operation 00 depending on
index,Table 6.167
Write operation depending on
index,Table 6.167
Przeglądanie stron 130