Wiring with Pico GFX-70 4-125
Inputs
The function block input >I1 can be assigned the following operands:
Constants
Markers MD, MW, MB
Analog inputs IA01 to IA04
IA01: terminal I7
IA02: terminal I8
IA03: terminal I11
IA04: terminal I12
Analog output QA01
Actual value
QV> of another function block
BCD code Decimal value
0001 1
0010 2
0011 3
0100 4
0101 5
0110 6
0111 7
1000 8
1001 9
1010 to 1111 Not permissible
10000 10
10001 11
IMPORTANT
The BCD code only allows the number range 0
hex
to 9
hex
.
The number range A
hex
to F
hex
cannot be represented. The
NC function block converts the impermissible range to 9.