6-18 Pico-Link and Point-to-Point Serial Connections
The normal rules for addressing the markers apply.
Configuration of the Serial Interface
The active station must have the following settings in order for the Serial
Interface connection to be functional:
Baud rate,
Serial Interface (active),
Remote marker range (data exchange range).
Active station Remote station
1 MD01
MD01
1 MW01 1MW02
MW01 MW02
1 MB01 1MB02 1MB03 1MB04
MB01 MB02 MB03 MB04
1 M01 to 1 M32
M01 to M32
1 MD02
MD02
1 MW03 1MW04
MW03 MW04
1 MB05 1 MB06 1 MB07 1 MB08
MB05 MB06 MB07 MB08
1 M33 to 1 M64
M33 to M64
1 MD03
MD03
1 MW05 1 MW06
MW05 MW06
1 MB09 1 MB10 1 MB11 1 MB12
MB09 MB10 MB11 MB12
1 M65 to 1 M96
M65 to M96
1 MD04
MD04
1 MW07 1 MW08
MW07 MW08
.....
....
....
1 MD20 MD20
1 MW39 1 MW40
MW39 MW40
1 MB77 1 MB78 1 MB79 1 MB80
MB77 MB78 MB79 MB80
IMPORTANT
Ensure a clear separation of the write range of the
two stations. The active station should write different
markers to the remote station. Otherwise the markers
in the last write operation will be overwritten.