Rockwell-automation 21G PowerFlex 750-Series AC Drives Programming Man Instrukcja Użytkownika Strona 211

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 210
Rockwell Automation Publication 750-PM001J-EN-P - October 2014 211
Drive Port 0 Parameters Chapter 3
APPLICATIONS
Id Compensation
1618 IdCompRegen 3 Iq
Id Compensation Regen 3 Iq
Sets Iq value (in p.u.) at which P1617 [Id Comp Regen 3] (in p.u.) is specified.
This parameter is active only in motor control mode flux vector induction (P35 [Motor
Cntrl Mode] = 3 “Induction FV”).
Default:
Min/Max:
0.7500
0.0000 / 5.0000
RW Real
1619 Id Comp Regen 4
Id Compensation Regen 4
Sets Id compensation value (in p.u.) at Iq = P1620 [IdCompRegen 4 Iq] (in p.u.) for
regenerative operation. Id compensation = Id Comp Regen 3 + (Id Comp Regen 4 – Id
Comp Regen 3) x (IqCmd – IdCompRegen 3 Iq) x 1/(IdCompRegen 4 Iq – IdCompRegen 3
Iq) for IqCmd = between IdCompRegen 3 Iq and IdCompRegen 4 Iq.
This parameter is active only in motor control mode flux vector induction (P35 [Motor
Ctrl Mode] = 3 “Induction FV”).
Default:
Min/Max:
0.0000
–/+1.0000
RW Real
1620 IdCompRegen 4 Iq
Id Compensation Regen 4 Iq
Sets Iq value (in p.u). at which P1619 [Id Comp Regen 4] (in p.u.) is specified.
This parameter is active only in motor control mode flux vector induction (P35 [Motor
Ctrl Mode] = 3 “Induction FV”).
Default:
Min/Max:
1.0000
0.0000 / 5.0000
RW Real
1621 Id Comp Regen 5
Id Compensation Regen 5
Sets Id compensation value (in p.u.) at Iq = P1622 [IdCompRegen 5 Iq] (in p.u.) for
regenerative operation. Id compensation = Id Comp Regen 4 + (Id Comp Regen 5 – Id
Comp Regen 4) x (IqCmd – IdCompRegen 4 Iq) x 1/(IdCompRegen 5 Iq – IdCompRegen 4
Iq) for IqCmd = between IdCompRegen 4 Iq and IdCompRegen 5 Iq.
This parameter is active only in motor control mode flux vector induction (P35 [Motor
Ctrl Mode] = 3 “Induction FV”).
Default:
Min/Max:
0.0000
–/+1.0000
RW Real
1622 IdCompRegen 5 Iq
Id Compensation Regen 5 Iq
Sets Iq value (in p.u.) at which P1621 [Id Comp Regen 5] (in p.u.) is specified.
This parameter is active only in motor control mode flux vector induction (P35 [Motor
Ctrl Mode] = 3 “Induction FV”).
Default:
Min/Max:
1.2500
0.0000 / 5.0000
RW Real
1623 Id Comp Regen 6
Id Compensation Regen 6
Sets Id compensation value (in p.u.) at Iq = P1624 [IdCompRegen 6 Iq] (in p.u.) for
regenerative operation. Id compensation = Id Comp Regen 5 + (Id Comp Regen 6 – Id
Comp Regen 5) x (IqCmd - IdCompRegen 5 Iq) x 1/(IdCompRegen 6 Iq – IdCompRegen 5
Iq) for IqCmd = between IdCompRegen 5 Iq and IdCompRegen 6 Iq.
This parameter is active only in motor control mode flux vector induction (P35 [Motor
Ctrl Mode] = 3 “Induction FV”).
Default:
Min/Max:
0.0000
–/+1.0000
RW Real
1624 IdCompRegen 6 Iq
Id Compensation Regen 6 Iq
Sets Iq value (in p.u.) at which P1623 [Id Comp Regen 6] (in p.u.) is specified.
This parameter is active only in motor control mode flux vector induction (P35 [Motor
Ctrl Mode] = 3 “Induction FV”).
Default:
Min/Max:
1.5000
0.0000 / 5.0000
RW Real
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type
755
755
755
755
755
755
755
1629 See page 67 for parameter numbers 1629 and 1637…1645.
1630 See page 64
for parameter numbers 1630…1636, 1646, and 1647.
1648 See page 58
for parameter numbers 1648…1661