244 Rockwell Automation Publication 750-PM001J-EN-P - October 2014
Chapter 5 Embedded Feature and Option Module Parameters
Embedded DeviceLogix
Status & Cntl
51 DLX DigOut Sts2
Provides the individual on/off status of the 16 DLX DOPs.
RO 32-bit
Integer
52 DLX Prog Cond
Defines the action that will be taken when the DLX logic is disabled.
“Fault” (0) – Drive is faulted and stopped.
“Stop” (1) – Drive is stopped, but not faulted.
“Zero Data” (2) – Output data sent to the drive from DLX is zeroed (does not command a
stop).
“Hold Last” (3) – Drive continues in its present state.
Default:
Options:
0 = “Fault”
0 = “Fault”
1 = “Stop
2 = “Zero Data”
3 = “Hold Last”
RW 32-bit
Integer
53 DLX Operation
Contains both operation commands as well as status information.
Default:
Options:
5 = “Logic Disabled”
0 = “Enable Logic”
1 = “Disable Logic”
2 = “Reset Program
3 = “Save Program
4 = “Load Program
5 = “Logic Disabled”
6 = “Logic Enabled”
RW 32-bit
Integer
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
DLX DOPSts16
DLX DOPSts15
DLX DOPSts14
DLX DOPSts13
DLX DOPSts12
DLX DOPSts11
DLX DOPSts10
DLX DOPSts9
DLX DOPSts8
DLX DOPSts7
DLX DOPSts6
DLX DOPSts5
DLX DOPSts4
DLX DOPSts3
DLX DOPSts2
DLX DOPSts1
Default00000000000000000000000000000000
Bit 313029282726252423222120191817161514131211109876543210
0 = Condition Off
1 = Condition On