Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 191
FactoryTalk View ME Configuration Chapter 5
Configure Additional Device Value Columns
Not all device faceplates used with the equipment status faceplate are configured to display four value fields. If
unused value fields are needed, then additional logic will need to be added to the existing device Add-On
Instruction to move the additional Add-On Instruction tag values to the corresponding Sts_Valuexx tags.
In this example, preconfigured logic within a FANUC CNC faceplate Add-On Instruction is used to write
values to Values 1, 2, 3, and 4. Simply remove or change these values by using the MOV instructions to move
other values to Values 1, 2, 3, or 4 if desired.