Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 91
GuardLogix Configuration Chapter 4
Import and Configure the Machine Logic Module
In this example, you add the preconfigured machine logic program file to your RSLogix5000 project and
configure it to your specific application.
1. Open your RSLogix 5000 software project that you
created in the previous section.
For the CNC Work Cell application example, the
CNC_Work_Cell project was opened.
2. Expand the Tasks folder in your Controller Organizer and
drag-and-drop the MainProgram folder to the
Unscheduled Programs / Phases folder.
3. Right-click the Main Task folder, and choose Import
Program.
4. Navigate to the 01_GuardLogix_Logic
folder within the toolkit’s files folder and
open the 01_Machine_Logic folder.
The file path is C:\Program
Files\RA_Simplification\CMAT\A-Files\
4-Controller Logic\01_GuardLogix_Logic.