52 Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012
Chapter 3 FANUC CNC Configuration
The chapter selection screen to display the
PMC configuration options is displayed.
3. Press the PMC CONFIG softkey.
4. Press either the + softkey or the right arrow
function key to advance to the chapter
selection for PMC online configuration, then
press ONLINE.
The chapter selection screen to display the
PMC online configuration options is
displayed.
5. Use the arrow keys on the
MDI panel to move to the
HIGH SPEED field, then
select USE.
The fast ethernet board is
now available to be
configured for the
EtherNet/IP application.