Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 43
System Layout and Wiring Chapter 2
Edit CNC System Layout Drawing
1. Open the panel layout drawing for your application.
For the CNC Work Cell application example, the
19_CNC_Panel_Layout.dwg file is opened.
The panel layout drawing includes sub-panel and enclosure
drawings. The panel is designed to accommodate
best-practice techniques used to minimize electrical noise.
Refer to the System Design for Control of Electrical Noise
Reference Manual, publication GMC-RM001.
2. Delete, replace, or add
component footprints to your
panel layout drawing.
To access Rockwell
Automation power
components, use the Drives
and Motion Accelerator
Toolkit DVD, publication
IASIMP-SP017. Navigate to
the CAD drawing libraries
layout section directories for a
variety of device footprints.
3. Delete, replace, or add
components to your
enclosure drawing.
To access Rockwell
Automation HMI or power
components, use the Drives
and Motion Accelerator
Toolkit DVD, publication
IASIMP-SP017
. Navigate to
the CAD drawing libraries
layout section directories for
a variety of device footprints.
CNC Subpanel Layout Drawing
CNC Enclosure Layout Drawing