Rockwell-automation SD3000 Drive Configuration, Programming Instrukcja Użytkownika Strona 65

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 118
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 64
Meter Port 2
1008 UDC Module Meter Port 2 Register Number Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDC Error Code:
N/A
LED:
N/A
Description: UDC register number (o-2044) to be mapped to meter port 2.
1007 UDC Module Meter Port 2 Bit Number Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDC Error Code:
N/A
LED:
N/A
Description: Bit number of the UDC register specified in register 1006 that is to be mapped to port 2.
Enter a value of 100 (bit 00) to 115 (bit 15) as required. Enter a value of zero if all of the register’s bits
are to be displayed.
1008 UDC Module Meter Port 2 Maximum Value Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDC Error Code:
N/A
LED:
N/A
Description: Set this register to the number that will represent
+10V.
The maximum allowable value
is 32767.
1009 UDC Module Meter Port 2 Minimum Value Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDC Error Code:
N/A
LED:
N/A
Description: Set this register to the number that will represent
-
1
0V.
The minimum allowable value
is -32768.