Meter Port 4
1014 UDG Module Meter Port 4 Register Number Register
Hex Value: N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDG Error Code:
N/A
LED:
N/A
Description: UDC register number (o-2044) to be mapped to meter port 4.
1015 UDG Module Meter Port 4 Bit Number Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDG Error Code:
N/A
LED:
N/A
Description: Bit number of the UDC register specified in register 1014 that is to be mapped to port 4.
Enter a value of 100 (bit 00) to 115 (bit 15) as required. Enter a value of zero if all of the register’s bits
are to be displayed.
1016 UDG Module Meter Port 4 Maximum Value Register
I
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDG Error Code:
N/A
LED:
N/A
Description: Set this register to the number that will represent
+1
0V. The maximum allowable value
is 32767.
1017 UDG Module Meter Port 4 Minimum Value Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDG Error Code:
N/A
LED:
N/A
Description:
Set this register to the number that will represent
-1
0V.
The minimum allowable value
is -32768.
3-47