Chapter 11
Coordinate Control
11-39
Programming
this G-code:
turnsZone 2: turnsZone 3:
G22 On On
G22.1 Off On
G23 Off Off
G23.1 No Change* Off
* AG23.1turnsonprogrammablezone2 if it isthedefault
powerupcondition configured in AMP(alsoactivatedat a
control reset). G23.1 does notturn on programmable zone2
when itis activated in a partprogram.
G23 is normally made active at power-up, though this is ultimately
determined by your system installer in AMP. Any zone that is activated in
a program or MDI block, remains active even after a control reset, E-STOP
reset, or end of program block (M02 or M30).
Important: If programming a G22, any axis words included in the block
are stored as the coordinates for programmable zone 3 (see page 11-40).
If an attempt is made to program some other command in a G22 or G23
block, other than a G code in the same modal group, for example:
G22 G01 X12.;
the control issues the error message:
“UNUSABLE WORDS IN ZONE BLOCK”
Figure 11.23
Programmable Zone 2
Software overtravel
Programmable
Zone 2
12023-I
For details on how the control reacts to entry into a prohibited area, see
page 11-43 on resetting overt ravel.