Publication 2098-RM003A-EN-P October 2001
Command Reference 2-113
Position Error
Positive Peak Position Error
Negative Peak Position Error
Velocity Command
Format: :aa081fddddddddcc<cr>
Parameter
Code:
0x081
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddddddd Position error, in units of counts.
Format: :aa082fddddddddcc<cr>
Parameter
Code:
0x082
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddddddd Peak positive position error, in units of counts.
Format: :aa083fddddddddcc<cr>
Parameter
Code:
0x083
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddddddd Peak negative position error, in units of counts.
Format: :aa084fddddddddcc<cr>
Parameter
Code:
0x084
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddddddd Velocity command, in units of counts/second.