Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Instrukcja Użytkownika Strona 35

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 176
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 34
Publication 2098-RM003A-EN-P October 2001
Command Reference 2-19
Broadcast Address
Reset Serial Port
Format: :aa053fddcc<cr>
Parameter
Code:
0x053
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x08 = Invalid Function Code
Data Fields: dd Broadcast address for serial communications.
Default: 0xFF
Format: :aa10Afcc<cr>
Parameter
Code:
0x10A
Valid Function
Codes:
0x1 = Write Working Value
Valid Exception
Codes:
0x06 = Command Disabled when Drive is Enabled
0x08 = Invalid Function Code
Data Fields: None
Przeglądanie stron 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 175 176

Komentarze do niniejszej Instrukcji

Brak uwag