Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Instrukcja Użytkownika Strona 68

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 176
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 67
Publication 2098-RM003A-EN-P October 2001
2-52 Command Reference
Positive Deceleration Distance
Negative Deceleration Distance
Format: :aa0DAfddddddddcc<cr>
Parameter
Code:
0x0DA
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddddddd Distance that an axis will travel when an overtravel
limit has been reached in the positive direction.
Minimum
Value:
0x00000000
Maximum
Value:
0x7FFFFFFF
Default: 0x00000000
Format: :aa0DBfddddddddcc<cr>
Parameter
Code:
0x0DB
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddddddd Distance that an axis will travel when an overtravel
limit has been reached in the negative direction.
Minimum
Value:
0x00000000
Maximum
Value:
0x7FFFFFFF
Default: 0x00000000
Przeglądanie stron 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 175 176

Komentarze do niniejszej Instrukcji

Brak uwag